This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Measuring principle
Differential pressure
-
Product headline
Calculated volume or mass flow measurement. dp primary element (orifice).
Orifice plate for existing flanges. -
Sensor features
Internationally standardized ISO5167-2.
Orifice plate only.
All tapping types possible.
Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.
Deltabar S/M differential pressure transmitter. -
Nominal diameter range
DN 25...1000
1" ... 40" -
Max. measurement error
typically < 1,5% of calculated volume or mass acc. ISO5167 without calibration.
Uncertainty of primary element excluding uncertainty of density or compensation. -
Measuring range
2.5 ... 150'000m3/h
-
Max. process pressure
PN6 ... 100
Cl.150 ... 2500 -
Medium temperature range
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F -
Degree of protection
Transmitter (Deltabar):
IP67
NEMA6P -
Display/Operation
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM -
Outputs
Transmitter (Deltabar):
4 ... 20 mA -
Digital communication
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
-
Measuring principle
Differential pressure
-
Product headline
Calculated volume or mass flow measurement. dp primary element (orifice).
Orifice plate for existing flanges. -
Sensor features
Internationally standardized ISO5167-2.
Orifice plate only.
All tapping types possible.
Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.
Deltabar S/M differential pressure transmitter. -
Nominal diameter range
DN 25...1000
1" ... 40" -
Max. measurement error
typically < 1,5% of calculated volume or mass acc. ISO5167 without calibration.
-
Measuring range
0.1 ... 15'000m3/h
-
Max. process pressure
PN6 ... 100
Cl.150 ... 2500 -
Medium temperature range
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F -
Degree of protection
Transmitter (Deltabar):
IP67
NEMA6P -
Display/Operation
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM -
Outputs
Transmitter (Deltabar):
4 ... 20 mA -
Digital communication
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI
-
Measuring principle
Differential pressure
-
Product headline
Calculated volume or mass flow measurement. dp primary element (orifice).
Orifice plate for existing flanges. -
Sensor features
Internationally standardized ISO5167-2.
Orifice plate only.
All tapping types possible.
Optimizable for minimized pressure loss, improved uncertainty or maximized Turndown.
Deltabar S/M differential pressure transmitter. -
Nominal diameter range
DN 25...1000
1" ... 40" -
Max. measurement error
typically < 1,5% of calculated volume or mass acc. ISO5167 without calibration.
Uncertainty of primary element excluding uncertainty of density or compensation. -
Measuring range
2.5 ... 150'000 m3/h
12.5 ... 750'000 kg/h at 10bar/230°C -
Max. process pressure
PN6 ... 100
Cl.150 ... 2500 -
Medium temperature range
Remote version:
-200°C ... 1000°C
-328°F ... 1832°F -
Degree of protection
Transmitter (Deltabar):
IP67
NEMA6P -
Display/Operation
Transmitter (Deltabar):
4-line display
3 push buttons
Quick setup
HistoROM -
Outputs
Transmitter (Deltabar):
4 ... 20 mA -
Digital communication
Transmitter (Deltabar):
HART
PROFIBUS PA
FOUNDATION Fieldbus -
Hazardous area approvals
Transmitter (Deltabar):
ATEX
FM
CSA
IEC
TIIS
NEPSI