Specs at a glance
-
Max. measurement error
Volume flow: ±0.5 % o.r. ± 1 mm/s (0.04 in/s)
-
Measuring range
4 dm³/min to 9600 m³/h (1 to 44 000 gal/min)
-
Medium temperature range
–10 to +110 °C (+14 to +230 °F)
-
Max. process pressure
PN 40, Class 150, 20K
-
Wetted materials
Liner: PTFE
Electrodes: 1.4435 (316L); Alloy C22, 2.4602 (UNS N06022)
Field of application
Promag E is a streamlined sensor for basic chemical applications. It is the most economical solution for our chemical customers. Combined with the Promag 10 transmitter for basic applications and direct integration, Promag 10E offers accurate measurement of liquids for a wide range of applications. It will be the preferred solution for customers aiming for minimized cost of ownership. Promag 10E is available as compact or remote version.
The measuring principle is virtually independent of pressure, density, temperature and viscosity
Fully suitable for basic applications in the chemical and process industry
Device properties
Nominal diameter: max. DN 600 (24")
All common process connections
Liner made of PTFE
2‐line display with push buttons
Device as compact or remote version
HART
Benefits
Cost-effective sensor – ideal solution for basic requirements
Energy-saving flow measurement – no pressure loss due to cross-section constriction
Maintenance-free – no moving parts
Cost-effective – designed for easily applications and direct integration
Safe operation – display provides easy readable process information
Fully industry compliant – IEC/EN/NAMUR
Videos
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Proline Promag 10E Technical Information
Electromagnetic flowmeter
EN 01/10/201701/04/2014Language:
English
Version:
01/10/2017
File size:
1.2 MB
File name:
TI01160DEN_0217.pdf
-
-
-
Operating Instruction (BA)
Proline Promag 10 HART Operating Instructions
Electromagnetic flowmeter
EN 27/11/201713/03/201709/02/201601/02/201501/04/2014Language:
English
Version:
27/11/2017
File size:
8.2 MB
File name:
BA00082DEN_1917.pdf
-
-
-
Short Instruction (KA)
Proline Promag 10 Brief Operating Instructions
Electromagnetic flowmeter
EN 27/11/201713/03/201704/04/201609/09/201501/02/2015Language:
English
Version:
27/11/2017
File size:
1008.4 KB
File name:
KA00032DEN_2017.pdf
-
-
-
Installation Instructions (EA)
Replacing cover and O-ring Installation Instructions
romag 10, 23, 50, 51, 53, 55, 400, 800, Promass 40, 80, 83, 84, 8ME, CNGmass 8FF, LPGmass 8FE, Cubemass 8CM, Prosonic Flow 90, 91,9 2, 93, t-mass 65,Prowirl 72, 73
EN 01/10/201828/06/2012Language:
English
Version:
01/10/2018
File size:
520.1 KB
File name:
EA00098DA2_1518.pdf
-
-
-
Installation Instructions (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN 01/03/201828/11/201325/04/2013Language:
English
Version:
01/03/2018
File size:
139.5 KB
File name:
EA01051DA2_0318.pdf
-
-
-
Installation Instructions (EA)
Replacing transmitter parts Installation Instructions
Promag 10, Prosonic Flow 91 W
EN 01/04/201917/11/2011Language:
English
Version:
01/04/2019
File size:
558.9 KB
File name:
EA00040DA2_1419.pdf
-
-
-
Installation Instructions (EA)
Replacing Sensor parts remote version Installation Instructions
Promag 10, 50, 51, 53, 55, 400, 800, Promass 80, 83, 84, Cubemass 8CN, CNGmass 8DF
EN 01/04/201928/06/2012Language:
English
Version:
01/04/2019
File size:
313.4 KB
File name:
EA00038DA2_1419.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter Installation Instructions
Promag 10, 23, 50, 53, 55
EN 01/04/201902/03/2010Language:
English
Version:
01/04/2019
File size:
1 MB
File name:
EA00082DA2_1119.pdf
-
-
-
Installation Instructions (EA)
Installing ground disks
Promag 10, 23, 50, 51, 53, 55, 100, 200, 300, 500, 800, 400 Index C
EN 09/10/202001/03/201815/07/2014Language:
English
Version:
09/10/2020
File size:
698.2 KB
File name:
EA00070DA2_1520.pdf
-
-
-
Installation Instructions (EA)
Interface parts Installation Instructions
Promag 10, 23, 50, 51, 53, 55,400, 800
EN 01/05/201728/06/2012Language:
English
Version:
01/05/2017
File size:
1.1 MB
File name:
EA00033DA2_1517.pdf
-