%20with%20flange%20connections%20for%20accurate%20measurement%20of%20natural%20and%20process%20gas%20-%20PP01.jpg)
Specs at a glance
-
Max. measurement error
Volume flow (standard):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Volume flow (optional calibration):
‐ ±0.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.0 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (standard):
‐ ±1.5 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±2.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Corrected volume flow (optional calibration):
‐ ±1.0 % o.r. for 3 to 40 m/s (9.84 to 131.23 ft/s)
‐ ±1.5 % o.r. for 0.3 to 3 m/s (0.98 to 9.84 ft/s)
Sound Velocity: ±0.2 % o.r. -
Measuring range
Gas: 0.3 m/s to 40 m/s
-
Medium temperature range
-50 to 150 °C (-58 to +302°F)
-50 to 100 °C (-58 to +212°F) with integrated pressure cell -
Max. process pressure
0.7 to 101 bar a (10.15 to 1464.88 psi a)
-
Wetted materials
Measuring tube: 1.4408/1.4409 (CF3M)
Transducer: 1.4404 (316, 316L, Titan Grade 2
Field of application
For a wide range of gas applications Prosonic Flow G provides reliable flow measurement, even with wet gas and changing gas properties and compositions. A pressure-rated sensor housing with rupture disc limits safety risks. The innovative remote transmitter maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology ensures compliance and process safety at all times.
The measuring principle is unaffected by gas composition
Accurate measurement of natural and process gas in the chemical as well as oil and gas industries.
Device properties:
Direct measurement: flow, pressure & temperature
Wetted parts: titanium / 316L
Maximum measuring accuracy: 0.5 %
Remote version with up to 4 I/Os
Backlit display with touch control and WLAN access
Standard cable between sensor and transmitter
Benefits
Flexible device with user-definable gas mixtures for demanding measuring tasks
Maximum reliability even with humid or wet gas – sensor design insensitive to condensate
High-performance process control – real-time pressure- and temperature-compensated values
Efficient solution – multivariable, no pressure loss
Full access to process and diagnostic information – numerous, freely combinable I/Os
Reduced complexity and variety – freely configurable I/O functionality
Integrated verification – Heartbeat Technology
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity

-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
-
Technical Information (TI)
Proline Prosonic Flow G 500 Техническое описание
Russian version - 09/2019
Ультразвуковой времяпролетный расходомер Высокопрочный прибор, специально разработанный для измерения газа при изменяющихся условиях технологического процесса в раздельном и сполнении с поддержкой до 4 входных/выходных сигналов
EN 16/09/201905/08/2019Language:
Russian
Version:
16/09/2019
File size:
5.9 MB
File name:
TI01386DRU_0219.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow G 500 HART Инструкция по эксплуатации
Russian version - 09/2019
Расходомеры-счетчики ультразвуковые
EN 16/09/201905/08/2019Language:
Russian
Version:
16/09/2019
File size:
8.2 MB
File name:
BA01836DRU_0219.pdf
-
-
-
Technical Information (TI)
Proline Prosonic Flow G 500 Technical Information
Ultrasonic time-of-flight flowmeter Highly robust gas specialist for fluctuating process conditions as remote version with up to 4I/Os
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
5.9 MB
File name:
TI01386DEN_0219.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow G 500 HART Operating Instructions
Ultrasonic time-of-flight flowmeter
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
8 MB
File name:
BA01836DEN_0219.pdf
-
-
-
Operating Instruction (BA)
Proline Prosonic Flow G 500 Modbus RS485 Operating Instructions
Ultrasonic time-of-flight flowmeter
EN 16/09/201905/08/2019Language:
English
Version:
16/09/2019
File size:
7.1 MB
File name:
BA01837DEN_0219.pdf
-
-
-
Device Parameter (GP)
Proline Prosonic Flow 500 HART Description of Device Parameters
Ultrasonic time-of-flight flowmeter
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
2.2 MB
File name:
GP01132DEN_0119.pdf
-
-
-
Device Parameter (GP)
Proline Prosonic Flow 500 Modbus RS485 Description of Device Parameters
Ultrasonic time-of-flight flowmeter
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
2.3 MB
File name:
GP01133DEN_0119.pdf
-
-
-
Short Instruction (KA)
Proline 500 – digital HART Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
1.1 MB
File name:
KA01377DEN_0119.pdf
-
-
-
Short Instruction (KA)
Proline 500 – digital Modbus RS485 Brief Operating Instructions
Transmitter with ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
1.1 MB
File name:
KA01378DEN_0119.pdf
-
-
-
Short Instruction (KA)
Proline Prosonic Flow G Brief Operating Instructions
Proline Prosonic Flow G Ultrasonic time-of-flight sensor
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
792.2 KB
File name:
KA01374DEN_0119.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronics
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 01/06/202131/07/202002/08/201902/01/201901/06/2018Language:
English
Version:
01/06/2021
File size:
1 MB
File name:
EA01145DA2_0621.pdf
-
-
-
Installation Instructions (EA)
Replacing Small parts
Promag 10, Promag, Promass 100, 500, CNG-, LNG-, LPGmass, Promag 400, 800 Index C, Prosonic Flow E 100, Prosonic Flow E Heat, Proson ic Flow, t-mass 500-digital
EN 01/05/202101/04/202131/07/202002/08/201901/03/2018Language:
English
Version:
01/05/2021
File size:
518.1 KB
File name:
EA01119DA2_0821.pdf
-
-
-
Installation Instructions (EA)
Replacing Small Parts
Promag 10, 400, 500, Promag 800 Index B, Promag 800Index C, Cubemass, Promag, Promass, Prosonic Flow, t-mass 400, 500-digital
EN 15/12/202101/05/202101/04/202101/06/202002/08/2019Language:
English
Version:
15/12/2021
File size:
1.2 MB
File name:
EA01024DA2_1121-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter Installation Instructions
Prosonic Flow 500-digital
EN 05/08/2019Language:
English
Version:
05/08/2019
File size:
324.5 KB
File name:
EA01264DA2_0119.pdf
-
-
-
Installation Instructions (EA)
Replacing the sensor, gasket for sensor and the pressure cell
Prosonic Flow G 300, 500-digital
EN 02/08/202215/02/202101/04/202030/09/201905/08/2019Language:
English
Version:
02/08/2022
File size:
766.4 KB
File name:
EA01254DA2_0522-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the Components for the Transmitter
Promag, Prosonic Flow 400, Promag 800 Index C, Promag, Promass, Prosonic Flow, t-mass 500-digital
EN 15/12/202101/11/202101/04/202101/06/202002/08/2019Language:
English
Version:
15/12/2021
File size:
2 MB
File name:
EA01094DA2_1121-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the display module
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital, DKX001–
EN 01/06/202131/07/202002/08/201902/01/201901/04/2017Language:
English
Version:
01/06/2021
File size:
712.1 KB
File name:
EA01144DA2_0621.pdf
-
-
-
Installation Instructions (EA)
Pipe mounting set
Proline 400, 500-digital
EN 15/12/202131/07/202002/08/201901/02/2017Language:
English
Version:
15/12/2021
File size:
503.9 KB
File name:
EA01195DA2_0421-00.pdf
-
-
-
Installation Instructions (EA)
Replacing the Display Protection
Promag 400, 800 Index C, Prosonic Flow 400, Promag, Promass, Prosonic Flow, t-mass 400, 500-digital
EN 15/12/202101/06/202002/08/201901/03/201801/08/2016Language:
English
Version:
15/12/2021
File size:
475.8 KB
File name:
EA01093DA2_0621-00.pdf
-
-
-
Installation Instructions (EA)
EA Protective Cover connection compartment
Proline 300, 500, 500, 500-digital
EN 01/06/202301/06/202131/07/202002/08/201902/01/2019Language:
English
Version:
01/06/2023
File size:
6.2 MB
File name:
EA01146DA2_0723-00.pdf
-
-
-
Installation Instructions (EA)
Alteration to Display module, to Display module with WirelessHART or Display module with WLAN
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 01/08/202131/07/202002/08/201902/01/201902/05/2018Language:
English
Version:
01/08/2021
File size:
1.4 MB
File name:
EA01158DA2_0721.pdf
-
-
-
Installation Instructions (EA)
Replacing the Sensor
Promag, Promass, Prosonic Flow 500-digital
EN 17/02/202015/09/201801/08/2016Language:
English
Version:
17/02/2020
File size:
540.7 KB
File name:
EA01157DA2_0320.pdf
-
-
-
Installation Instructions (EA)
Kit wireless antenna for extended range
Promag, Promass, Prosonic Flow 300, 400, 500, 500-digital, t-mass 300, 500-digital
EN 28/03/202201/06/202131/07/202005/08/201902/01/2019Language:
English
Version:
28/03/2022
File size:
1.3 MB
File name:
EA01238DA2_0622-00.pdf
-
-
-
Installation Instructions (EA)
Replacing ISEM electronics module, ISEM extender, ribbon cable
Promag, Promass, Prosonic Flow 300, 500, 500-digital, t-mass 300, 500-digital
EN 02/08/202202/05/202201/06/202101/02/202005/08/2019Language:
English
Version:
02/08/2022
File size:
1.7 MB
File name:
EA01147DA2_0722-00.pdf
-
-
-
Installation Instructions (EA)
Alteration pressure cell
Prosonic Flow 300, 500-digital
EN -