Краткие характеристики
-
Сертификаты для взрывоопасных зон
ATEX, CSA, IECEx
Область применения
The Raman Rxn-30 probe has cross-industry appeal for its robust gas-phase headspace monitoring, in situ measurements, and material compatibility. Certified for use in hazardous area environments, the Raman Rxn-30 probe can be inserted directly into processes with temperatures up to 150 degrees Celsius and pressures up to 68.9 barg (1,000 psig). It is available with a variety of mounting options for maximum installation and sampling flexibility.
Chemical: ammonia, methanol, HyCO, reaction monitoring, blending, catalysis
Polymer: polymerization reaction monitoring
Gas-phase streams in refining: hydrogen production and recycle fuel blending, fuel characterization
Power & Energy: IGCC power plants, gas turbines
Pharmaceutical: API reaction monitoring, drying
Food & Beverage: fermentations, offgas, volatiles
Преимущества
Reliable, quantitative gas-phase measurements
In situ measurement/no transfer lines or fast loops required
Can be directly inserted into processes with temperatures up to 150 °C and 68.9 barg (1,000 psig)
Industry standard installation options
Direct insertion, side insertion, or sample loop
Suitable for hazardous area/classified environments
Выбор варианта Extended
-
Высокотехнологичные продукты
- Функциональность и удобство
Технический уровень
Простота
-
Стандартные продукты
- Надежность, прочность и неприхотливость
Технический уровень
Простота
-
Высокотехнологичные продукты
- Функциональность и удобство
Технический уровень
Простота
-
Специализированные продукты
- Для требовательных областей применения
Технический уровень
Простота
Вариативность
Выбор категории FLEX | Технический уровень | Простота |
---|---|---|
Выбор варианта Fundamental Выполнение основных измерительных задач |
Технический уровень
|
Простота
|
Выбор варианта Lean Простое управление основными процессами |
Технический уровень
|
Простота
|
Выбор варианта Extended Оптимизация процессов с помощью инновационных технологий |
Технический уровень
|
Простота
|
Выбор варианта Xpert Управление самыми сложными областями применения |
Технический уровень
|
Простота
Вариативность |
Ранняя версия
-
-
Техническое описание (TI)
Rxn-30 Raman Spectroscopic Probe Technical Information
System design and specifications for the Raman Rxn-30 probe
Язык:
Английский
Версия:
01/07/2022
Размер файла:
569.9 KB
Имя файла:
TI01632CEN_0222.pdf
-
-
-
Руководство по эксплуатации (BA)
Rxn-30 Raman spectroscopic probe Operating Instructions
Commissioning, operation, and maintenance details
for the Raman Rxn-30 probeEN RU 28/06/2022Язык:
Английский
Версия:
28/06/2022
Размер файла:
1.1 MB
Имя файла:
BA02168CEN_0222.pdf
-
-
-
Краткая инструкция (KA)
Rxn-30 Raman Spectroscopic Probe Brief Operating Instructions
Quick start guide for the Raman Rxn-30 probe
Язык:
Английский
Версия:
01/07/2022
Размер файла:
624.9 KB
Имя файла:
KA01548CEN_0222.pdf
-
-
-
Указания по взрывозащите (XA)
Инструкции по безопасности для волоконно-оптического зонда спектрометра комбинационного рассеяния Rxn-30
Сертификаты для опасных зон и инструкции по установке
волоконно-оптического зонда Rxn-30EN RU 10/07/202421/06/202408/08/2023Язык:
Русский
Версия:
10/07/2024
Размер файла:
1.3 MB
Имя файла:
XA02748CRU_0424.pdf
-
-
-
PU (публикация)
石油・ガスおよび化学産業向け ラマン分光計アプリケーションガイド - ガスストリームおよびLNGの組成分析
化学産業および石油・ガス産業におけるガスストリームおよび LNG の組成分析用(Raman Rxn4 アナライザー、
Raman Rxn5 アナライザー、Raman Rxn-30 プローブ、Raman Rxn-41 プローブを含む)、
Kaiser Raman テクノロジーによるラマン分光アナライザーおよびプローブ製品ラインアップのご案内です。Язык:
Японский
Версия:
13/05/2024
Размер файла:
4.2 MB
Имя файла:
PU01445CJA_0121_RamanAnalyzer_AppGuide_OilGas_ChemInd.pdf
-
-
-
PU (публикация)
Raman Rxn5 analyzer - Laser-based composition analysis
An overview brochure about our Raman Rxn5 analyzer (including
the Raman Rxn-30 probe, the Rxn-40 probe, and the Rxn-41 probe),
a Raman spectroscopy analyzer system for gas phase measurements
powered by Kaiser Raman technology.Язык:
Английский
Версия:
28/10/2021
Размер файла:
499.9 KB
Имя файла:
PU01444CEN_0121.pdf
-
-
-
PU (публикация)
Raman analyzer application guide for the oil & gas and chemical industries - Composition analysis of gas streams and LNG
A guide to our Raman spectroscopy analyzer and probe portfolio,
powered by Kaiser Raman technology, for composition analysis of
gas streams and LNG (includes the Raman Rxn4 analyzer, the
Raman Rxn5 analyzer, the Raman Rxn-30 probe, and
Raman Rxn-41 probe) in the chemical industry and oil & gas industry.Язык:
Английский
Версия:
08/12/2021
Размер файла:
2.5 MB
Имя файла:
PU01445CEN_0121.pdf
-
-
-
PU (публикация)
Industry standards on gas quality - Raman Rxn5 analyzer (syngas/LNG) andRaman Rxn4 analyzer (LNG)
A list of industry gas quality standards that our Raman Rxn5
analyzer meets for syngas / LNG and our Raman Rxn4
analyzer meets for LNG.Язык:
Английский
Версия:
20/04/2022
Размер файла:
432.5 KB
Имя файла:
PU01463CEN_0122.pdf
-
-
-
PU (публикация)
Raman Rxn-30 probe - Gas phase analysis
An overview brochure about the Raman Rxn-30 probe, a
Raman spectroscopy probe for gas phase measurement
powered by Kaiser Raman technology in the Oil & Gas
industry and Chemical industry.Язык:
Английский
Версия:
20/01/2022
Размер файла:
489.6 KB
Имя файла:
PU01452CEN_0122.pdf
-
-
-
Инновации (IN)
Raman spectrographic probes - Robust optical measurement of chemical composition
An overview brochure about our Raman spectroscopy probe
portfolio including the Rxn-10 probe, Rxn-20 probe, Rxn-30 probe,
Rxn-40 probe, Rxn-41 probe, Rxn-45 probe, Rxn-46 probe, and
probe accessory optics (bIO-Optic, Raman single use optic system /
SUB, immersion optic , non-contact optic), powered by Kaiser Raman
technology.Язык:
Английский
Версия:
26/10/2021
Размер файла:
4.9 MB
Имя файла:
IN01225CEN_0121.pdf
-
-
-
Инновации (IN)
Mesure optique robuste de la composition chimique
-
Язык:
French
Версия:
16/03/2023
Размер файла:
776 KB
Имя файла:
IN01225CFR.pdf
-
-
-
Инновации (IN)
ラマン分光プローブ - 堅牢な分光分析による化学組成分析
ラマン分光法プローブ製品ラインナップに関する概要パンフレットです。
この製品ラインナップには、Rxn-10プローブ、Rxn-20プローブ、Rxn-30プローブ、
Rxn-40プローブ、Rxn-41プローブ、Rxn-45プローブ、Rxn-46プローブ、
およびプローブオプティクアクセサリ(bIOオプティック、
シングルユース向けラマンオプティックシステム/SUB、浸漬オプティック、
非接触オプティック)が含まれています。
これらはすべて、Kaiserラマンテクノロジーによって動作します。Язык:
Японский
Версия:
24/06/2024
Размер файла:
5.4 MB
Имя файла:
IN01225CJA_0121_Raman_spectroscopic_probes.pdf
-
-
-
Инновации (IN)
Raman technology for the chemical industry - Reliable composition measurement of chemical process streams
An overview brochure about our Raman spectroscopy analyzer systems,
powered by Kaiser Raman technology, for the chemical industry
(includes the Raman Rxn2 analyzer, Raman Rxn4 analyzer,
Raman Rxn5 analyzer, and the Raman Rxn-10 probe, Raman Rxn-20 probe,
Raman Rxn-30 probe, Raman Rxn-40 probe, and Raman Rxn-41 probe).Язык:
Английский
Версия:
18/10/2021
Размер файла:
10.6 MB
Имя файла:
IN01223CEN_0121.pdf
-
-
-
Инновации (IN)
化学産業におけるラマン技術
プロセスラインにおける信頼性の高い組成測定
Язык:
Японский
Версия:
01/03/2023
Размер файла:
16.5 MB
Имя файла:
IN01223CJA_0121.pdf
-
-
-
Информационная статья (WP)
Getting a hydrogen signal in natural gas
This whitepaper discusses the role of Raman spectroscopy (using a
Raman Rxn5 analyzer and Rxn-30 probe) to safely control the injection
of H₂ (hydrogen blending) in natural gas which is an important focus in
energy transition.Язык:
Английский
Версия:
13/09/2022
Размер файла:
1.6 MB
Имя файла:
WP01184CEN_0122.pdf
-
-
-
AI (примечание по применению)
Captive hydrogen: fuel gas to reformer furnaces
This application note examines the use of a Raman Rxn5 analyzer for
the measurement of fuel gas streams to reformer furnaces.Язык:
Английский
Версия:
15/10/2021
Размер файла:
594.9 KB
Имя файла:
AI01265CEN_0121.pdf
-
-
-
AI (примечание по применению)
Captive hydrogen: CO2 absorber outlet - feed to PSA
This application note examines the use of a Raman Rxn5 analyzer for
the measurement of CO2 absorber outlet stream to PSA.Язык:
Английский
Версия:
15/10/2021
Размер файла:
567.3 KB
Имя файла:
AI01270CEN_0121.pdf
-
-
-
AI (примечание по применению)
LNG: natural gas liquefaction
Thisapplication note examines the use of a Raman Rxn5 analyzer
to measure the composition of mixed refrigerant in the LNG
liquefaction process.Язык:
Английский
Версия:
03/12/2021
Размер файла:
371 KB
Имя файла:
AI01346CEN_0121.pdf
-
-
-
AI (примечание по применению)
Captive hydrogen: PSA unit H2 stream
This application note examines the use of a Raman Rxn5 analyzer for
the measurement of the PSA outlet to H2 stream.Язык:
Английский
Версия:
15/10/2021
Размер файла:
669.2 KB
Имя файла:
AI01271CEN_0121.pdf
-
-
-
AI (примечание по применению)
SNG: CO2 recovery stream
This application note discusses the use of a Raman Rxn5 analyzer to
measure CO2 recovered from the CO2 absorber unit.Язык:
Английский
Версия:
16/11/2021
Размер файла:
596.2 KB
Имя файла:
AI01342CEN_0121.pdf
-