Conductive
Point level detection
One rod probe 11961Z

Probe 11961Z ©Endress+Hauser

High resistance point level detection of conductive liquids steam boilers and aggressive media

The 11961Z is a highly resistant probe for applications with aggressive medium thanks to corrosion-resistant materials for rod and insulation. It can be used in steam boilers thanks to ceramic insulation resistant to steam and hot water.

  • Преимущества

    • Safe and reliable measurement even in aggressive medium thanks to corrosion-resistant materials for rod and insulation

    • Can be used in steam boilers thanks to ceramic insulation resistant to steam and hot water

    • Can be deployed particularly with high...

  • Область применения

    For conductive point level detection in process or storage tanks, for conductivity as of 0.02mS/cm. As overfill prevention with line monitoring even in Ex-area Zone 0, or pump protection in pipes and two-point control.

    • Process connection: Thread

    • ...

Details

  • Принцип измерения

    Кондуктивный принцип измерения

  • Характеристики/Применение

    Стержневой зонд для применений при очень высоких температурах и давлении. Стойкость к коррозийному износу.

  • Питание / Коммуникация

    Реле
    ЧИМ

  • Температура окружающей среды

    -200 °C ... 250 °C

  • Рабочая температура

    -200 °C ... 250 °C

  • Рабочее давление абс. / макс. предел избыточного давления

    Вакуум ... 160 бар

  • Мин. проводимость среды

    20 мкСм/см

  • Смачиваемые части

    Керамика, 316TI

  • Присоединение к процессу

    G 1/2

  • Длина датчика

    0.1м ... 2м

  • Связь

    Реле

  • Сертификаты безопасности

    Защита от перелива WHG

  • Компоненты

    Преобразователь: FTW325

  • Диапазон применения

    Мин. проводимость среды

Документы / руководства пользователя / программное обеспечение

Аксессуары / Запчасти

Nr
Order code
Specification
  • Ранняя версия