Specs at a glance
-
Max. measurement error
Volume flow (liquid): ±0.75 %
Volume flow (steam, gas): ±1.00 %
Mass flow (saturated steam): ±1.7% (temperature compensated); ±1.5% (temperature/pressure compensated)
Mass flow (superheated steam, gas): ±1.5 (temperature/pressure compensated); ±1.7% (temperature compensated + external pressure compensation)
Mass flow (liquid): ±0.85% -
Measuring range
Liquid: 0.1 to 1700 m³/h (0.061 to 1000 ft³/min)
depending on medium: water with 1 bar a, 20 °C (14.5 psi a, 68° F)
Steam, gas: 0.52 to 22000 m³/h (0.31 to 13000 ft³/min)
depending on medium: steam with 180 °C, 10 bar a (356 °F, 145 psi a); air with 25 °C, 4.4 bar a (77 °F, 63.8 psi a) -
Medium temperature range
Standard: –40 to +260 °C (–40 to +500 °F)
High/low temperature (option): –200 to +400 °C (–328 to +752 °F) -
Max. process pressure
PN 250, Class 1500, 40K
-
Wetted materials
Measuring tube: 1.4408 (CF3M)
DSC sensor: UNS N07718 similar to Alloy 718, 2.4668
Process connection: 1.4404/F316/F316L
Field of application
Prowirl O is ideally suited for reliable process control in demanding gas and steam applications with high process pressure. Moreover, its design ensures maximum safety in main and ancillary processes. With genuine loop-powered technology, Prowirl O 200 enables cost-effective and seamless integration into existing infrastructures. It offers highest operational safety in hazardous areas. Heartbeat Technology enables process safety at all times.
Preferred measuring principle for wet/saturated/superheated steam, gases & liquids (also cryogenic)
The specialist for applications with high process pressure
Device properties
Saturated steam mass flow up to PN 250 (Class 1500)
Full compliance with NACE (MR0175/MR0103)
Flexible positioning of pressure cell
Display module with data transfer function
Robust dual-compartment housing
Plant safety: worldwide approvals (SIL, Haz. area)
Benefits
Better process control – integrated temperature and pressure measurement for steam and gases
Increased mechanical integrity for flow measurement – special sensor design
Same accuracy down to Re 10 000 – most linear Vortex meter body
Long-term stability – robust drift-free capacitive sensor
Convenient device wiring – separate connection compartment, various Ethernet options
Safe operation – no need to open the device
Integrated verification – Heartbeat Technology
Videos
Extended selection
-
High-end products
- Highly functional and convenient
Technical excellence
Simplicity
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
Predecessor
-
-
Technical Information (TI)
Proline Prowirl O 200
English version - 06/2020
Vortex flowmeter
EN 21/06/202023/01/202002/04/201801/01/2018Language:
English
Version:
21/06/2020
File size:
4.3 MB
File name:
TI01334DEN_0420.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline Prowirl O Brief Operating Instructions
English version - 12/2018
Proline Prowirl O Vortex flow sensor
EN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
710.9 KB
File name:
KA01324DEN_0218.pdf
-
-
-
Technical Information (TI)
Proline Prowirl O 200
Vortex flowmeter
EN 21/06/202023/01/202002/04/201801/01/2018Language:
English
Version:
21/06/2020
File size:
4.3 MB
File name:
TI01334DEN_0420.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl O 200 PROFIBUS PA
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
4.4 MB
File name:
BA01691DEN_0220.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl O 200 HART
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
4.4 MB
File name:
BA01687DEN_0220.pdf
-
-
-
Operating Instruction (BA)
Proline Prowirl O 200 FOUNDATION Fieldbus
Vortex flowmeter
EN 21/06/202001/01/2018Language:
English
Version:
21/06/2020
File size:
5 MB
File name:
BA01695DEN_0220.pdf
-
-
-
Device Parameter (GP)
Proline Prowirl 200 HART Description of Device Parameters
Vortex flowmeter
EN 01/07/201901/01/2018Language:
English
Version:
01/07/2019
File size:
2.1 MB
File name:
GP01109DEN_0219.pdf
-
-
-
Device Parameter (GP)
Proline Prowirl 200 FOUNDATION Fieldbus Description of Device Parameters
Vortex flowmeter
EN 01/07/201901/01/2018Language:
English
Version:
01/07/2019
File size:
2.4 MB
File name:
GP01111DEN_0219.pdf
-
-
-
Device Parameter (GP)
Proline Prowirl 200 PROFIBUS PA Description of Device Parameters
Vortex flowmeter
EN 01/01/2018Language:
English
Version:
01/01/2018
File size:
1.8 MB
File name:
GP01110DEN_0118.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 200 Brief Operating Instructions
FOUNDATION Fieldbus transmitter
with vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
1.7 MB
File name:
KA01327DEN_0218.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 200 Brief Operating Instructions
Profibus PA transmitter
with vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
1.7 MB
File name:
KA01328DEN_0218.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline 200 Brief Operating Instructions
HART transmitter
with vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
1.4 MB
File name:
KA01326DEN_0218.pdf
-
-
-
Short Instruction (KA)
Flowmeter Proline Prowirl O Brief Operating Instructions
Proline Prowirl O
Vortex flow sensorEN 03/12/201801/01/2018Language:
English
Version:
03/12/2018
File size:
710.9 KB
File name:
KA01324DEN_0218.pdf
-
-
-
Installation Instructions (EA)
EA Conversion Kit for Prowirl 200 Compact Version to Prowirl 200 Remote Version
Prowirl 200 non explosion-protected
EN 16/10/202301/02/202203/03/202001/05/201723/04/2015Language:
English
Version:
16/10/2023
File size:
1.4 MB
File name:
EA01055DA2_0623-00.pdf
-
-
-
Installation Instructions (EA)
Safety Instructions for Spare Parts Installation Instructions
Flowmeter
EN 01/03/201828/11/201325/04/2013Language:
English
Version:
01/03/2018
File size:
139.5 KB
File name:
EA01051DA2_0318.pdf
-
-
-
Installation Instructions (EA)
Replacing the display module Installation Instructions
Promag 200, Promass 200, Prosonic Flow 200, Prowirl 200, t-mass 150,
Levelflex FMP5x, Micropilot FMR5x, Micropilot FMR6x, Remote dis
play FHX50EN 01/09/201701/02/201724/11/201528/11/201306/04/2012Language:
English
Version:
01/09/2017
File size:
562.2 KB
File name:
EA00102DA2_1817.pdf
-
-
-
Installation Instructions (EA)
Replacing the connection board, pre amplifier, cable harness Installation Instructions
Prowirl 200
EN 01/12/201702/12/2013Language:
English
Version:
01/12/2017
File size:
770.5 KB
File name:
EA01086DA2_0217.pdf
-
-
-
Installation Instructions (EA)
Replacing the electronics module Installation Instructions
Prowirl 200
EN 01/12/201702/12/2013Language:
English
Version:
01/12/2017
File size:
500.1 KB
File name:
EA01088DA2_0217.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the I/O-Module
Proline 200
EN 01/07/202301/10/201818/12/2013Language:
English
Version:
01/07/2023
File size:
633.9 KB
File name:
EA01092DA2_0323-00.pdf
-
-
-
Installation Instructions (EA)
Alteration of the pressure measuring cell
Prowirl 200 Index C
EN 14/11/202201/06/202119/02/2021Language:
English
Version:
14/11/2022
File size:
664.1 KB
File name:
EA01332DA2_0322-00.pdf
-
-
-
Installation Instructions (EA)
Replacing measuring unit, measuring cell, seal Installation Instructions
Prowirl 200
EN 01/12/2017Language:
English
Version:
01/12/2017
File size:
712.8 KB
File name:
EA01232DA2_0117.pdf
-
-
-
Installation Instructions (EA)
Replacing the transmitter Installation Instructions
Prowirl 200
EN 01/12/201713/02/201502/12/2013Language:
English
Version:
01/12/2017
File size:
743.4 KB
File name:
EA01056DA2_0317.pdf
-
-
-
Installation Instructions (EA)
Replacing the cover, O-ring cover and the housing seal Installation Instructions
Prowirl 200 Remote Version
EN 01/10/201802/12/2013Language:
English
Version:
01/10/2018
File size:
305.6 KB
File name:
EA01087DA2_0218.pdf
-
-
-
Installation Instructions (EA)
EA Replacing the DSC-Sensor, S-DAT and gasket
Prowirl 200
EN 16/10/202302/03/202001/03/201801/12/2017Language:
English
Version:
16/10/2023
File size:
1.5 MB
File name:
EA01228DA2_0423-00.pdf
-
-
-
Installation Instructions (EA)
Activating application packages
Promag 100, 200, 400, Promass 100, 200, Prosonic Flow 100, 200, Prowirl
200, t-mass 150EN 03/03/202015/02/2019Language:
English
Version:
03/03/2020
File size:
406.9 KB
File name:
EA01249DA2_0220.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Prowirl 200
EAC:
0Ex ia IIC T6 … T1 Ga
Ga/Gb Ex ia IIC T6 … T1
1Ex ia IIC T6 … T1 Gb
Ex tb IIIC T** °C DbEN 15/12/2023Language:
English
Version:
15/12/2023
File size:
605.5 KB
File name:
XA01782DEN_0223-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Prowirl 200
EAC:
Ga/Gc Ex ic [ia] IIC T6...T1
2Ex ic IIC T6...T1 Gc
2Ex ic [ia Ga] IIC T6...T1 Gc
2Ex ec IIC T6...T1 Gc
2Ex ec [ia Ga] IICT6...T1 GcEN 15/12/2023Language:
English
Version:
15/12/2023
File size:
627.1 KB
File name:
XA01685DEN_0223-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200
UKEX:
II2G, II1/2G, II1G Ex ia IIC T6 … T1
II2D Ex tb IIIC Txx °CLanguage:
English
Version:
01/12/2021
File size:
554.7 KB
File name:
XA02631DEN_0121-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Prowirl 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex d versionEN 20/11/202315/02/202301/12/201801/06/2018Language:
English
Version:
20/11/2023
File size:
650.6 KB
File name:
XA01643DEN_0423-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Prowirl 200
NEPSI:
Zone 2
Ex ec and Ex ic versionEN 20/11/202322/03/202315/02/202301/12/201801/06/2018Language:
English
Version:
20/11/2023
File size:
662.9 KB
File name:
XA01645DEN_0523-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Prowirl 200
NEPSI:
Zone 1, Zone 0/1, Zone 21
Ex i versionEN 20/11/202322/03/202315/02/202301/12/201801/06/2018Language:
English
Version:
20/11/2023
File size:
657.8 KB
File name:
XA01644DEN_0523-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200
INMETRO:
Zone 1, Zone 0/1, Zone 0
Ex i versionEN 03/04/2023Language:
English
Version:
03/04/2023
File size:
563.6 KB
File name:
XA01640DEN_0222-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200
JPN:
Zone 1, Zone 0/1
Zone 21
Ex d versionEN 01/03/2021Language:
English
Version:
01/03/2021
File size:
586.2 KB
File name:
XA01766DEN_0221.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200 ATEX: II2G, II1/2G Ex db[ia] IIC T6 … T1 II2D Ex tb IIIC Txx °C IECEx: Zone 1, Zone 0/1 Ex db[ia] IIC T6 … T1 Zone 21 Ex tb IIIC Txx °C Safety Instructions
Documentation for hazardous areas
EN 01/01/2018Language:
English
Version:
01/01/2018
File size:
407.6 KB
File name:
XA01635DEN_0118.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200 Zone 0 Class I, II, III, Division 1 IS (Ex i Intrinsically safe version) Safety Instructions
Documentation for hazardous area
Language:
English
Version:
01/01/2018
File size:
262 KB
File name:
XA01639DEN_0118.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200 Zone 1 Class I, II, III, Division 1 XP (Ex d Flameproofed version) Safety Instructions
Documentation for hazardous area
Language:
English
Version:
01/01/2018
File size:
246.5 KB
File name:
XA01638DEN_0118.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200 ATEX: II3G Ex ec, II3G Ex ic, II1/3G Ex ic[ia] IIC T6 … T1 IECEx: Zone 2 Ex ec, Zone 2 Ex ic, Zone 0/2 Ex ic[ia] IIC T6 … T1 Safety Instructions
Documentation for hazardous areas
EN 01/01/2018Language:
English
Version:
01/01/2018
File size:
431.2 KB
File name:
XA01637DEN_0118.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200 ATEX: II2G, II1/2G, II1G Ex ia IIC T6 … T1 II2D Ex tb IIIC Txx °C IECEx: Zone 1, Zone 0/1, Zone 0 Ex ia IIC T6 … T1 Zone 21 Ex tb IIIC Txx °C Safety Instructions
Documentation for hazardous areas
EN 01/01/2018Language:
English
Version:
01/01/2018
File size:
423.8 KB
File name:
XA01636DEN_0118.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200
INMETRO:
Zone 1, Zone 0/1
Ex d versionEN 03/04/2023Language:
English
Version:
03/04/2023
File size:
547 KB
File name:
XA01642DEN_0222-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200
INMETRO:
Zone 2EN 03/04/2023Language:
English
Version:
03/04/2023
File size:
568.1 KB
File name:
XA01641DEN_0222-00.pdf
-
-
-
Ex Safety Instruction (XA)
XA Proline Prowirl 200
EAC:
Ga/Gb Ex db [ia] IIC T6…T1
1Ex db [ia] IIC T6…T1 Gb
Ex tb IIIC T** °C DbEN 15/12/2023Language:
English
Version:
15/12/2023
File size:
579.8 KB
File name:
XA01684DEN_0223-00.pdf
-
-
-
Ex Safety Instruction (XA)
Proline Prowirl 200
UKEX:
II2G, II1/2G Ex db[ia] IIC T6 … T1
II2D Ex tbIIIC Txx °CLanguage:
English
Version:
01/12/2021
File size:
535.7 KB
File name:
XA02630DEN_0121-00.pdf
-