Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
The bio multi optic is a critical part for easy, reliable, real-time bioprocess measurements with maximum sterility and efficiency. The non-contact multi optic features a patented self-aligning lens for top spectral quality and reproducibility. It pairs with the Rxn-10 probe and connects to an autoclavable (or gamma sterilizable), disposable bio sleeve via an easy snap-in-place design. The system reduces maintenance and cross-contamination risk for reusable or single-use benchtop bioreactors.
Benchtop bioreactors to measure glucose, lactate, amino acids, cell density, titer and more
Benchtop fermenters to measure glycerol, methanol, ethanol, sorbitol, biomass, and more
Use with flow assembly CYA680 for select downstream bioprocessing applications
Improved ease of use and reduced maintenance for bioprocessing
Simplified workflow for greater process efficiency – swap out probes mid-batch, use multiple sleeves in the same reactor for simplified redundancy, and calibrate / verify probes at any time
Optimized spectral performance when used with a compatible bio sleeve
Высокотехнологичные продукты
Технический уровень
Простота
Стандартные продукты
Технический уровень
Простота
Высокотехнологичные продукты
Технический уровень
Простота
Специализированные продукты
Технический уровень
Простота
Вариативность
Выбор категории FLEX | Технический уровень | Простота |
---|---|---|
Выбор варианта Fundamental Выполнение основных измерительных задач |
Технический уровень
|
Простота
|
Выбор варианта Lean Простое управление основными процессами |
Технический уровень
|
Простота
|
Выбор варианта Extended Оптимизация процессов с помощью инновационных технологий |
Технический уровень
|
Простота
|
Выбор варианта Xpert Управление самыми сложными областями применения |
Технический уровень
|
Простота
Вариативность |
System design and specifications for the multi optic calibration
and verification kit
Язык: |
Английский |
Версия: |
26/06/2023 |
Размер файла: |
478.7 KB |
Имя файла: |
TI01719CEN_0123 Multi optic calibration and verification kit.pdf |
System design and specifications for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL),
and Raman optic system for single use (KRSU1)
EN | RU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Язык: |
Английский |
Версия: |
31/05/2023 |
Размер файла: |
467.9 KB |
Имя файла: |
TI01635CEN_0322.pdf |
System design and specifications
for the Raman Rxn-10 probe
Язык: |
Английский |
Версия: |
31/05/2023 |
Размер файла: |
423 KB |
Имя файла: |
TI01629CEN_0322.pdf |
Commissioning, operation, and maintenance details
for Rxn-10 probe optics: Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | RU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Язык: |
Английский |
Версия: |
31/05/2023 |
Размер файла: |
1.8 MB |
Имя файла: |
BA02171CEN_0322.pdf |
Commissioning, operation, and maintenance details for the
multi optic calibration and verification kit
Язык: |
Английский |
Версия: |
26/06/2023 |
Размер файла: |
996.4 KB |
Имя файла: |
BA02294CEN_0123 Multi optic calibration and verification kit.pdf |
Commissioning, operation, and maintenance details
for the Raman Rxn-10 probe
Язык: |
Английский |
Версия: |
31/05/2023 |
Размер файла: |
1.2 MB |
Имя файла: |
BA02160CEN_0322.pdf |
Quick start guide for the Raman Rxn-10 probe
Язык: |
Английский |
Версия: |
31/05/2023 |
Размер файла: |
895.3 KB |
Имя файла: |
KA01546CEN_0322.pdf |
Quickstart guide for Rxn-10 probe optics:
Raman immersion optics (KIO1),
non-contact optics (KNCO1), bIO-Optics (KLBIO1),
bio multi optics (KRBMO), bio sleeves (KRBSL)
and Raman optic system for single use (KRSU1)
EN | RU | ||
31/05/2023
|
|
|
|
03/08/2022
|
|
|
Язык: |
Английский |
Версия: |
31/05/2023 |
Размер файла: |
1 MB |
Имя файла: |
KA01551CEN_0322.pdf |
Graphic highlighting why Endress+Hauser is trusted by the
world's top biopharmaceutical manufacturers for its Life
Sciences expertise and reliable inline, real-time measurement
technologies like Raman spectroscopy systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology (Liquiline CM44P, CM442 and
OUSAF44, OUSBT66 and Memosens CPS61E, CLS82E, COS81E,
CLS82E).
Язык: |
Английский |
Версия: |
27/06/2024 |
Размер файла: |
1.9 MB |
Имя файла: |
PU01585CEN_0124.pdf |
This technical paper studies the importance of scalability as a
competitive advantage in bioprocessing in the Life Science industry,
and Endress+Hauser's scalable Raman systems (Raman Rxn2,
Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and sleeve,
flow cell and flow bench, Raman optic system for single use) and
liquid analysis sensor technology and Liquid Analysis portfolio
(Liquiline CM44P, CM442 and OUSAF44, OUSBT66 and
Memosens CPS61E, CLS82E, COS81E, CLS82E).
Язык: |
Чешский |
Версия: |
06/09/2024 |
Размер файла: |
381.4 KB |
Имя файла: |
PU01584CEN_0124_cz_view.pdf |