Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
785 нм
Температура: зонд не контактирует со средой; рабочая температура: 10...50 °C / 50...122 °F
The union between our Raman analyzers equipped with Rxn-46 bioprocess probe technology and the BioPAT® Spectro platform by Sartorius offers the market an ideal interface to high-throughput development through single-use commercial manufacturing. Our Raman bioprocessing probe technology has been adapted to fit Sartorius’s BioPAT® Spectro platform, utilizing the same probe design for Ambr® 15, Ambr® 250, & Biostat STR® bioreactors.
Cell culture: glucose, lactate, amino acids, cell density, titer, and more
Enables faster, easier, and more robust model building via integration with Ambr® 15 and Ambr® 250
Allows high-throughput process development which supports QbD
Provides a more efficient transfer to Biostat STR® for single-use manufacturing
Offers a scale-independent interface from 15 ml in the laboratory to 2000 L in the production suite
Requires no probe cleaning, sterilization, or frequent maintenance due to non-contact sampling
Стандартные продукты
Технический уровень
Простота
Высокотехнологичные продукты
Технический уровень
Простота
Специализированные продукты
Технический уровень
Простота
Вариативность
| Выбор категории FLEX | Технический уровень | Простота |
|---|---|---|
Выбор варианта Fundamental Выполнение основных измерительных задач |
Технический уровень
|
Простота
|
Выбор варианта Lean Простое управление основными процессами |
Технический уровень
|
Простота
|
Выбор варианта Extended Оптимизация процессов с помощью инновационных технологий |
Технический уровень
|
Простота
|
Выбор варианта Xpert Управление самыми сложными областями применения |
Технический уровень
|
Простота
Вариативность |
Конструкция системы и технические характеристики
спектроскопического зонда Raman Rxn-46
| EN | RU | ||
|
29/10/2025
|
|
|
|
|
11/03/2025
|
|
|
|
|
13/12/2024
|
|
|
|
|
11/01/2024
|
|
|
|
|
03/08/2022
|
|
|
|
Язык: |
Русский |
|
Версия: |
29/10/2025 |
|
Размер файла: |
425.4 KB |
|
Имя файла: |
TI01634CRU_0525.pdf |
System design and specifications for the Raman Rxn-46
calibration and verification kit
| EN | RU | ||
|
11/01/2024
|
|
|
|
Язык: |
Английский |
|
Версия: |
11/01/2024 |
|
Размер файла: |
400.4 KB |
|
Имя файла: |
TI01765CEN_0123.pdf |
Подробности ввода в эксплуатацию, эксплуатации и
обслуживания зонда Raman Rxn‑46
| EN | RU | ||
|
29/10/2025
|
|
|
|
|
14/01/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
11/01/2024
|
|
|
|
|
03/08/2022
|
|
|
|
Язык: |
Русский |
|
Версия: |
29/10/2025 |
|
Размер файла: |
1.3 MB |
|
Имя файла: |
BA02170CRU_0525.pdf |
Commissioning, operation, and maintenance details for the
Raman Rxn-46 calibration and verification kit
| EN | RU | ||
|
11/01/2024
|
|
|
|
Язык: |
Английский |
|
Версия: |
11/01/2024 |
|
Размер файла: |
928.9 KB |
|
Имя файла: |
BA02324CEN_0123.pdf |
Краткое руководство по эксплуатации спектроскопического
зонда Raman Rxn-46
| EN | RU | ||
|
06/02/2025
|
|
|
|
|
02/12/2024
|
|
|
|
|
11/01/2024
|
|
|
|
|
03/08/2022
|
|
|
|
|
14/09/2021
|
|
|
|
Язык: |
Русский |
|
Версия: |
06/02/2025 |
|
Размер файла: |
678.5 KB |
|
Имя файла: |
KA01550CRU_0424.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Язык: |
Английский |
|
Версия: |
26/06/2025 |
|
Размер файла: |
363.4 KB |
|
Имя файла: |
PU01611CEN_0125.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Язык: |
Английский |
|
Версия: |
22/05/2025 |
|
Размер файла: |
481.6 KB |
|
Имя файла: |
PU01614CEN_0125.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
|
Язык: |
Японский |
|
Версия: |
04/10/2024 |
|
Размер файла: |
2.5 MB |
|
Имя файла: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
Ein Leitfaden zu unseren Anwendungshinweisen zur
Raman-Spektroskopie für die Life-Science-Industrie
(Raman Rxn2-Analysator, Raman Rxn4-Analysator,
Rxn-10-Sonde, Rxn-20-Sonde, Rxn-45-Sonde,
Rxn-46-Sonde und Zubehör für Sondenoptiken
(blO-Optic, Raman- Single Use-Optiksystem
/ SUB, Immersionsoptik, berührungslose Optik)
|
Язык: |
Немецкий |
|
Версия: |
24/09/2025 |
|
Размер файла: |
1.4 MB |
|
Имя файла: |
PU01447CDE_0222_Raman-Anwendungsleitfaden_LSI_web.pdf |
A guide to our Raman spectroscopy application notes for the
Life Science industry (featuring the Raman Rxn2 analyzer,
Raman Rxn4 analyzer, Rxn-10 probe, Rxn-20 probe, Rxn-45 probe,
Rxn-46 probe, and probe accessory optics (bIO-Optic, Raman single
use optic system / SUB, immersion optic, non-contact optic).
|
Язык: |
Английский |
|
Версия: |
19/04/2022 |
|
Размер файла: |
1.1 MB |
|
Имя файла: |
PU01447CEN_0222.pdf |