Levelflex M FMP45
This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Documents / Manuals / Software
-
Levelflex M FMP41C, FMP45
Technical Information
Guided Level-Radar
Continuous Level Transmitter for
'- Level Measurement in Liquids
'- Interface Measurement in LiquidsTechnical Information (TI) -
Accessory
Centering star PEEK
Operating Instruction (BA) -
Levelflex M FMP45
PROFIBUS PA
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Operating Instruction (BA) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PA, FF
Description of Instrument Functions
Smart Transmitter for continuous
level measurement in liquidsOperating Instruction (BA) -
Levelflex / Levelflex M
Zentrierscheibe / Centering disk (PFA)
Mounting Instructions
Accessory
Operating Instruction (BA) -
Levelflex M FMP45
FOUNDATION Fieldbus
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Operating Instruction (BA) -
Levelflex M FMP45
HART
Operating Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Operating Instruction (BA) -
Levelflex M FMP40, FMP41C, FMP45
Measurement
Guided Level Radar for Interface Measurement with HART
Operating Instruction (BA) -
Levelflex M FMP45
Interface measurement
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for interface measurement in liquids.Operating Instruction (BA) -
Levelflex M FMP45
Interface measurement
Brief
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for interface measurement in liquids.Short Instruction (KA)11/10English -
Levelflex M FMP45
FOUNDATION Fieldbus
Brief
Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10English -
Levelflex M FMP45
PROFIBUS PA
Brief Operating
Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10English -
Levelflex M FMP45
HART
Brief Operating Instructions
Guided Level Radar
Continuous Level Transmitter for level measurement in liquids.Short Instruction (KA)11/10English -
Weather protection cover
Mounting Instruction
Weather protection cover for devices with F12/T12/F23 housing.
Short Instruction (KA)06/07German , English , Spanish , fr , Italian , Dutch -
FMP4x - Exchange of housing F12
FMP4x - Exchange of housing F12
Short Instruction (KA)04/21German , English -
FMP4x - exchange of housing T12
FMP4x - exchange of housing T12
Short Instruction (KA)04/21German , English -
FMU4x, FMP4x - Exchange of power module for housing F12 (Netzteil)
FMU4x, FMP4x - Exchange of power module for housing F12 (Netzteil)
Short Instruction (KA)04/21German , English -
Exchange of probe rod/rope on Levelflex M FMP40, FMP45
Exchange of probe rod/rope on Levelflex M FMP40, FMP45
Short Instruction (KA)04/12German , English -
Levelflex M FMP40, FMP41C, FMP45
HART, PROFIBUS PA, FOUNDATION Fieldbus
Leveflex M Kurzanleitung/Brief operating instructions
HART, PROFIBUS PA, FOUNDATION FieldbusShort Instruction (KA)04/09German , English -
Levelflex M FMP40, FMP41C, FMP43, FMP45
HART, PROFIBUS PA, FOUNDATION Fieldbus
Leveflex M Kurzanleitung/Brief operating instructions
HART, PROFIBUS PA, FOUNDATION FieldbusShort Instruction (KA)03/07German , English -
Operating Instructions - mounting the probe rod
Smart Transmitter for continuous level measurement in liquids.
Short Instruction (KA)03/04German , English , Spanish , fr , Italian , Japanese , Dutch , Chinese -
Nordlock disc, counter nut, threaded pin for FMP5x, FMP4x
Installation instruction
Levelflex, Levelflex M
Installation Instructions (EA) -
Terminal module for housing F12/F23
Installation Instruction
Micropilot M, Levelflex M, Prosonic M
Installation Instructions (EA) -
Cable separate version
Installation Instructions
Cerabar M, Cerabar S, Deltabar S, Deltapilot M, Deltapilot S
Installation Instructions (EA) -
HF module
Installation instruction
Levelflex M
Installation Instructions (EA) -
Electronics for Levelflex M
Installation instruction
Levelflex M
Installation Instructions (EA) -
Electronic module (Interface measurement)
Installation instruction
Levelflex M, FMP40, FMP41C, FMP43, FMP45
Installation Instructions (EA) -
Divisible rod probe for Levelflex M
Installation instruction
Levelflex M, FMP40, FMP45
Installation Instructions (EA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
EG 11 005
II 3 G
Protection: Ex ic IIC T6...T1 GcEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G resp. Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1;
II 1/2 D, II 1/3D, II 3 D resp. Zone 20/21, Zone 20/22, Zone 22 Ex tD
xx IP68 Txx°CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex d [ia] IIC T6...T3
Zone 0/1, Zone 1
Protection: Ex d [ia] IIC T6...T3Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109
II 1/2 D, II 2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx°CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Safety Instructions
Micropilot M, Levelflex M, Prosonic M
FM Control Drawing
EMC C-module for ToF apparatus
Cl. I, II, III, Div. 2, Group A, B, C, D, E, F, G
and Cl. I, Zone 2, Group IIC
NIFW installationEx Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex d ia [ia Ga] IIC T6...T1 Ga/Gb
GYJ12.1261X (NEPSI)Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
EG 11 005
II 3 G
Protection: Ex ic IIC T6...T1 GcEx Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex emb [ia] IIC T6...T1
GYJ101291 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
4-20 mA HART
Ex ia IIC T6...T1
GYJ111018 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP45
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex nA IIC T6...T1 Gc
GYJ12.1453X (NEPSI)Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
II 1/2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx°CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
II 1/2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx°CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
IECEx TUN 04.0010
Ex tD A20/21 or A21 IP68 T115°C
Ex tD A20/22 or A22 IP68 T83 °CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109
ATEX II 1/2 D, II 2 D IP68 T115 °C
II 1/3 D, II 3 D IP68 T83 °CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 D, II 2 D, II 1/3 D, II 3 D
Protection: Ex tD xx IP68 Txx °C
Zone 20/21,Zone 21, Zone 20/22, Zone 22
Protection: Ex tD xx IP68 Txx °CEx Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex e mb [ia] IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex em [ia] IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP43, FMP45
Approval No.: EG 05 017-b
II 3 G
Protection: Ex nA II T6...T1 XEx Safety Instructions (XA) -
Safety Instructions
Levelflex M FMP40, FMP43, FMP45
PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T6...T1
GYJ111018 (NEPSI)Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP45
KEMA 02 ATEX 1109, IECEx TUN 04.0010
II 1/2 G, II 2 G
Protection: Ex ia IIC T6...T1
Zone 0/1, Zone 1
Protection: Ex ia IIC T6...T1Ex Safety Instructions (XA) -
Levelflex M FMP40, FMP41C, FMP45
Allgemeine bauaufsichtliche Zulassung
Z-65.16.354Certificate (ZE) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2171 D, 960409-2174 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2179 C, 960409-2180 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2178 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
HART
CSA
Drawing No.: 960409-2175 B Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2172 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1178 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Grounding of screen variations
Screen grounding
Certificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2170 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1172 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
PROFIBUS PA, FOUNDATION Fieldbus
CSA
Drawing No.: 960409-2176 B, 960409-2177 B Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
PROFIBUS PA, FOUNDATION Fieldbus
FM
Drawing No.: 960409-1171 C, 960409-1174 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1173 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
PROFIBUS PA, FOUNDATION Fieldbus
FM
Drawing No.: 960409-1179 B, 960409-1180 B Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
PROFIBUS PA, FOUNDATION Fieldbus
FM
Drawing No.: 960409-1176 B, 960409-1177 B Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
HART
FM
Drawing No.: 960409-1170 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
HART
FM
Drawing No.: 960409-1175 B Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1171 D, 960409-1174 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
PROFIBUS PA, FOUNDATION FIeldbus
CSA
Drawing No.: 960409-2171 C, 960409-2174 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
FM
Drawing No.: 960409-1172 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
HART
CSA
Drawing No.: 960409-2173 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2176 C, 960409-2177 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2175 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
HART
CSA
Drawing No.: 960409-2170 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1179 C, 960409-1180 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2173 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
HART
FM
Drawing No.: 960409-1178 B Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
FM
Drawing No.: 960409-1173 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
CSA
Drawing No.: 960409-2172 E
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1176 C, 960409-1177 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1170 D
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP43, FMP45
Drawing No.: 960409-1175 C
Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP45
CSA
Drawing No.: 960409-2172 C Drawing Type: Control drawingCertificate FM/CSA (ZD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Functional Safety Manual
Guided level-radar for liquids and bulk solids
Special Documentation (SD) -
Levelflex M FMP45, Levelflex M FMP45 + process transmitter RMA422
Safety instructions for steam boiler approval
Special Documentation (SD) -
Tie-on label
Tie-on label
Special Documentation (SD) -
Levelflex FMP54, Levelflex M FMP45
Notice
Please unscrew transport protection prior to installation!Special Documentation (SD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Levelflex M FMP40, FMP41C, FMP43, FMP45
Micropilot M FMR230, FMR231, FMR240, FMR244, FMR245, FMR250
Hinweis zur Montage
Füllstand-Radar für Flüssigkeiten und Schüttgütern
Geführtes Füllstand-Radar für Flüssigkeiten und SchüttgüterSpecial Documentation (SD) -
Levelflex FMP51, FMP54
Mounting the probe rod
Levelflex FMP51, FMP54
Mounting the probe rodSpecial Documentation (SD) -
Simatic PDM HART Package 1.14.00
Manufacturer Information includes PDM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.14.00Manufacturer Information (MI) -
AMS FOUNDATION fieldbus Package V1.06.00
Manufacturer Information includes AMS - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.06.00Manufacturer Information (MI) -
AMS HART Package V1.12.00
Manufacturer Information includes AMS - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
Levelflex M FMP40, FMP41C, FMP45
Manufacturer Information for users regarding software updates(NE53)
Software version V01.04.00 HART / PROFIBUS PA
Manufacturer Information (MI) -
PRM HART Package V1.08.00
Manufacturer Information includes PRM - Device List, Release Notes –
HART
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.08.00Manufacturer Information (MI) -
Simatic PDM PROFIBUS Package V1.12.00
Manufacturer Information includes PDM - Device List, Release Notes –
PROFIBUS
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.12.00Manufacturer Information (MI) -
PRM FOUNDATION fieldbus Package V1.05.00
Manufacturer Information includes PRM - Device List, Release Notes –
FOUNDATION fieldbus
Manufacturer Information for users regarding software updates
(following the NAMUR recommendation 53)
New software version: 1.05.00Manufacturer Information (MI) -
Profibus PA
Firmware 1.04.02
Manufacturer Information (MI) -
Manufacturer information for users regarding software updates (NE53)
Manufacturer information for users regarding software updates (NE53)
Manufacturer Information (MI) -
Please fill in. (You can find example text among the HELP menu)
Please fill in. (You can find example text among the HELP menu)
Manufacturer Information (MI) -
Napędy i Sterowanie styczeń 2008
Modernizacja pływakowych lub nurnikowych pomiarów poziomu
Publications (PU)08/09Polish -
Przetworniki poziomu Levelflex NiS_02_2011
Nowa rodzina innowacyjnych radarów falowodowych Levelflex
Evolution SeriesPublications (PU)04/12Polish -
Nap&
281;dy i Sterowanie kwiecie&
324; 2007
Detekcja ko&
324;ca sondy
w radarach falowodowychPublications (PU)04/07Polish -
Przetworniki poziomu - art CE 04/2011
Przetworniki poziomu
Jednoczesne wytwarzanie ciepła i energii elektrycznej, czyli kogeneracja
to w ostatnich latach niezwykle popularne zagadnienie w polskiej
energetyce cieplnej i zawodowej. Pozwala ona na obniżenie poziomu
zużycia węgla w procesie wytwarzania energii. Ograniczenie emisji do
atmosfery szkodliwych gazów oraz zmniejszenie strat energii między
wytwórcą i odbiorcą.
Składowanie biomasy w elektrociepłowni lub w elektrowni.
Pomiary ilości biomasy w silosach magazynowych.Publications (PU)03/12Polish -
Füllstandmessung in Dampfkesseln
Nach EN 12952/12953, Hochwasser (HW), Niedrigwasser (NW)
Competence Brochure (CP)05/14German -
Levelflex M FMP45 in boiler control
Levelflex M FMP45 measures hot water in super heated steam boilers in
large public utilityCase Studies (CS)07/10English -
Level measurement in heating oil
Levelflex M - FMP45 with coax probe and Memograph S recorder provide
leak monitoring in heating oil tankCase Studies (CS)06/10English -
Levelflex M (high temperature/high pressure) displacer replacer
Levelflex M, FMP45 is used to measure level in a liquefied gas (Butane
Diol)Case Studies (CS)06/10English -
Radarowe pomiary poziomu wody w walczaku
Przebadane przez Centralne Laboratorium Dozoru Technicznego
Innovations (IN)05/12Polish -
Levelflex M Guided Level-Radar via PROFIBUS PA o the PlantPAx Process
Automation System
System using a 1788HP-EN2PA Linking Device
Integration DocumentSystem Partner (SP)05/09English -
Levelflex M Guided Level-Radar via HART to the PlantPAx Process
Automation System
System using a ControlLogix 1756 HART Analog Input Module
Integration DocumentSystem Partner (SP)01/09English -
GSD Single, GSD_EH_PA_LE_Levelflex_0x152D_V01_00_PALIB, 14.04.2014 (Level
, Levelflex M, 0x152D)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x02_FFLIB_ITK5_00, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.00Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x01_FFLIB_ITK4_61, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.61Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_LevelflexM_0x152D_0x04_0x01, 07.01.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x03_0x01_FFLIB_ITK4_01, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.01Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexFMP4x_0x0012_0x04_0x05, 01.10.2015 (Level, Levelflex M)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.1 SP1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x03_0x03_FFLIB_ITK4_60, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 4.60Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexM_0x0020_0x08_0x08, 07.11.2018 (Level, Levelflex M, 0x0020)
HART,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_LevelflexM_0x152D_0x02_0x01, 07.01.2019 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
PDM Version: 6.0 SP5Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_LevelflexFMP4x_0x0012_0x02_0x02, 01.10.2015 (Level, Levelflex M)
HART,
PDM Version: 6.0 SP5, 6.1, 8.1, 8.2Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_LevelflexM_0x1012_0x04_0x03_FFLIB_ITK5_20, 09.11.201
6 (Level, Levelflex M, 0x1
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: ITK 5.20Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, LevelflexM_FMP4x_FF_V4_xx_DevRev4, 22.10.2020 (Level, Levelflex M, 0x1012)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V2_00___2_02, 20.10.2020 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V2_04, 20.10.2020 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V2_06, 20.10.2020 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP4x_PA_V4_xx, 20.10.2020 (Level, Levelflex M, 0x152D)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, LevelflexM_FMP40_V2_00, 23.10.2020 (Level, Levelflex M, 0x0012)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, LevelflexMInt_FMP4xI_V1_08, 23.10.2020 (Level, Levelflex M, 0x0020)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
DTM Single, LevelflexM_FMP4x_V4_xx, 23.10.2020 (Level, Levelflex M, 0x0012)
HART,
DeviceCare Version: 1.07.00
Field Device Manager Version: R430.1
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.12Faceplate1.05.00Language neutral -
Product Family: Levelflex M
Product Code: FMP45-, FMP41C-, FMP40-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.0Fieldbus ConformanceEnglish -
Product Family: Levelflex M
Product Code: FMP40-, FMP45-, FMP41C-, FMP43-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 04, DD-ITK 5.20Fieldbus ConformanceEnglish
Accessories / Spare parts
-
-
Order code 52006628
Instrument plug M20-M12 "PA" (WDM)150
4-pin metall plug for installation in the device, providing connection to a T-Box (WDM) or cable socket (WDM). Cable length: 150mm. Not suitable for PROMAG and PROMAG.
-
-
-
Nr 12 Order code 535720-9020
Set of screws housing F12/T12/F23
Consists of: 1x stop screw M5x10. 1x retaining screw M8x10. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
-
-
Order code 543199-0001
Protective cover for housing T12/F12, SS
Usage: Micropilot M, Micropilot S, Prosonic M, Levelflex M. Material: 316Ti.
-
-
-
Nr 20 Order code 517391-0011
Cover F12/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44.
-
Nr 20 Order code 52005936
Cover F12/T12 Alu, window, gasket
Material: aluminium. Usage: VU331, housing F12/T12, Micropilot M/S, Prosonic M, Levelflex M.
-
Nr 20 Order code 52018670
Cover F23 316L, sight glass, gasket
Material: 316L. Usage: VU331, Levelflex M, Micropilot M.
-
Nr 20 Order code 52018671
-
-
-
Nr 25 Order code 518710-0020
Cover T3/T12 Alu, coated, gasket
Material: aluminium, coated. O-ring EPDM. Usage: FMR230/FMR231,FMR240/FMR244/ FMR245, FMR250, FMR530/FMR531/FMR532/ FMR533, FMR540, FMU40/FMU41/FMU42.
-
-
-
Nr 11 Order code 52006026
Cover terminal compartment F12/F23
Hood terminal compartment. Usage: Micropilot M, Prosonic M, Levelflex M.
-
Nr 11 Order code 52019062
Cover terminal compartment F12/F23,FHX40
Hood terminal compartment. Usage: separate display, Micropilot M, Prosonic M, Levelflex M.
-
-
-
Nr 35 Order code 52006197
Terminal module 4-pole, HART, 2-wire
Cable connection. Usage: housing F12/F23, Micropilot M, Levelflex M, Prosonic M.
-
Nr 35 Order code 52012156
Terminal module 4-pole, PA, FF
PROFIBUS PA, FOUNDATION Fieldbus. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Nr 35 Order code 52013302
Terminal mod. Ex d, 4-pol., 2wr,HART,T12
Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
Nr 35 Order code 52013303
Terminal mod. Ex d, 2-pol.,2wr,PA/FF,T12
2-wire, PROFIBUS PA/FOUNDATION Fieldbus. Ex d limiter. Usage: housing T12, Levelflex M, Micropilot M, Prosonic M.
-
Nr 35 Order code 52018949
Terminal mod. 4-pol.,EEx ia,HART,T12,OVP
4-pole, 2-wire. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
Nr 35 Order code 52018950
Terminal mod. 2-p.,EEx ia,PA/FF,T12,OVP
2-pole, 2-wire. PROFIBUS PA, FOUNDATION Fieldbus. OVP = overvoltage protection. Usage: housing T12, Levelflex M, Prosonic M, Micropilot M.
-
-
-
Nr 11 Order code 52005643
Hood housing T12
Cable compartment, electronics side. Usage: Micropilot M/S, Prosonic M, Levelflex M.
-
-
-
Nr 35 Order code 52013304
Power supply 10.5-32VDC (housing F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52013305
Power supply 90-250VAC (housing F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015585
Power supply CSA, 10.5-32VDC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
Nr 35 Order code 52015586
Power supply CSA, 90-250VAC (housg F12)
Usage: electronics 4-wire, Levelflex M, Prosonic M.
-
-
-
Nr 40 Order code 52026443
Display VU331, version 2
Alphanumeric display, 4-line. Usage: FMR530/532/533, FMR540, FMU40/41/42/43/44.
-
-
-
Order code 52013874
-
Order code 52014249
Isolation tie down of the 4mm rope probe
Isolator: PPS. Ring bolt: stainless steel. Usage: FMP40, FMP56.
-
-
-
Nr 59 Order code 71023427
Nordlock washer DIN25201-A4, M10, 5 pcs.
6mm rope/16mm rod, 4mm rope flange version, thread G1-1/2, NPT1-1/2. Usage: FMP40/FMP45, FMP57, divisible rod FMP40/FMP45, FMP51/FMP54.
-
-
-
Order code FHX40-
Display FHX40
Remote display + local operation. 4-line LC-display. :: Menu driven plain text operation. :: Easy setup. :: User language selectable. :: Envelope curve display on site. Usage: FMG60, FMU40/FMU41/FMU42/FMU43/FMU44.
-
Order code 52018204
Adaption kit housing F12, 2-wire, FHX40
Modification to remote display. Housing F12, 2-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Micropilot II/M, Prosonic M, Levelflex M.
-
Order code 52018205
Adaption kit housing F12, 4-wire, FHX40
Modification to remote display. Housing F12, 4-wire electronics. Non-hazardous area only. Please order FHX40 separately. Usage: Levelflex M, Prosonic M.
-
Order code 52016334
-
Order code 71020502
-
Order code 71020503
-
Order code 71020504
-
Order code 71156686
-
Order code 71007843
ToF Adapter FXA291
Usage: connection Micropilot M, Micropilot S, Levelflex M, Prosonic M, Tank Side Monitor, Deltabar S, Cerabar S, Gammapilot M, Micropilot I, to Commubox FXA291.
-
Order code 52028063
HF-test cable 6GHz + resistor
Coax cable. Termination resistor / connection piece. Usage: FMR530/FMR532/FMR533, FMR540. Dummy antenna.
-
Order code 71000221
Adapterk. FMR2xx,FMx4x,PMx7x,FMD7x,FMG60
Connection service tool RS232(52013675)/ ToF adapter FXA291 (71007843). Usage: FMG60, FMD77/FMD78, FMR230/ FMR231, FMR240/FMR244/FMR245, FMR250, FMU40/FMU41/FMU42/FMU43/FMU44, NRF590, PMC71, PMD75, PMP71/PMP75.
-
Order code 71006590
HF-test cable 6GHz
Coax cable. Usage: FMR230/FMR231, FMR530/FMR531/FMR532/FMR533, FMR540. Dummy antenna.
-
Order code
Phase out spares
-
Order code
12/2017
-
-
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-