This product is no longer available.
Please check new generation in the section predecessor / successor or contact your local Endress+Hauser entity.
Predecessor
-
Successor
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections Technical excellence Simplicity - F
- L
- E
- X
Fundamental selection
Meet your basic measurement needs
Technical excellence Simplicity - F
- L
- E
- X
Lean selection
Handle your core processes easily
Technical excellence Simplicity - F
- L
- E
- X
Extended selection
Optimize your processes with innovative technologies
Technical excellence Simplicity - F
- L
- E
- X
Xpert selection
Master your most challenging applications
Technical excellence Simplicity Variable
-
-
Measuring principle
Coriolis
-
Product headline
The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, EHEDG, FDA
-
Measuring principle
Coriolis
-
Product headline
The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A,, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, EHEDG, FDA
-
Measuring principle
Coriolis
-
Product headline
The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Other approvals and certificates
3.1 material, calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR, SIL, marine
PED, CRN, AD 2000
3-A, FDA
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, EHEDG, FDA
-
Measuring principle
Coriolis
-
Characteristic / Application
The universal and multivariable flowmeterfor liquids and gases
-
Ambient temperature
-20...+65°C
(-4...+140°F) -
Process temperature
-50...+350°C
(-58...+662°F) -
Process pressure
PN 16...100
Cl 150...600
JIS 10...63K -
Wetted parts
904L/1.4539
Alloy C-22 -
Output
4...20mA
Pulse/Frequency
Status -
Certificates / Approvals
ATEX
FM
CSA
TIIS
-
Measuring principle
Coriolis
-
Product headline
The robust flowmeter for demanding applications with a compact or remote transmitter. Highest measurement performance for liquids and gases under varying, demanding process conditions.
-
Sensor features
Highest process safety – immune to fluctuating and harsh environments. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in/outlet run needs. Mass flow: measurement error ±0,05 % (PremiumCal). pressure-rated sensor housing up to 40 bar (580 psi).
-
Transmitter features
Cost‐effective – dedicated design for standard applications. Safe operation – display provides easy readable process information. Fully industry compliant – IEC/EN/NAMUR. 2‐line backlit display with push buttons. Device in compact or remote version.
-
Nominal diameter range
DN 8 to 250 (⅜ to 10")
High temperature: DN 25 (1"), DN 50 (2"), DN 80 (3") -
Wetted materials
Measuring tube: 1.4539 (904L); 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022)
Connection: 1.4404 (316/316L); Alloy C22, 2.4602 (UNS N06022) -
Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density
-
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), 0.1 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.35 %
Density (liquid): ±0.0005 g/cm³ -
Measuring range
0 to 2 200 000 kg/h (0 to 80 840 lb/min)
-
Max. process pressure
PN 100, Class 600, 63K
-
Medium temperature range
Standard: –50 to +200 °C (–58 to +392 °F)
High temperature: –50 to +350 °C (–58 to +662 °F) -
Ambient temperature range
Standard: –20 to +60 °C (–4 to +140 °F)
Option: –40 to +60 °C (–40 to +140 °F) -
Sensor housing material
1.4301/1.4307 (304L), corrosion resistant
-
Transmitter housing material
Powder‐coated die‐cast aluminium
1.4301 (304), sheet
CF3M (316L), cast -
Degree of protection
IP67, type 4X enclosure. Remote transmitter: IP67, type 4X enclosure
-
Display/Operation
2‐line backlit display with push buttons
Configuration via local display and operating tools possible -
Outputs
3 outputs:
0‐20 mA (active)/4‐20 mA (active/passive)
Pulse/frequency/switch output (passive) -
Inputs
Status input
-
Digital communication
HART
PROFIBUS PA -
Power supply
DC 16 to 62 V
AC 85 to 260 V (45 to 65 Hz)
AC 20 to 55 V (45 to 65 Hz) -
Hazardous area approvals
ATEX, IECEx, FM, CSA, NEPSI
-
Product safety
CE, C-tick, EAC marking
-
Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511
-
Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025), NAMUR
-
Marine approvals and certificates
Marine approval
-
Pressure approvals and certificates
PED, CRN, AD 2000
-
Material certificates
3.1 material
NACE MR0175/MR0103, PMI; welding test acc. to EN, ASME,NORSOK -
Hygienic approvals and certificates
3-A, EHEDG, FDA
-
-
Technical Information (TI)
Information technique Proline Promass 80F, 80M, 83F, 83M
-
Technical Information (TI)
French version - 06/2008New version available in EnglishDébitmètre massique Coriolis.
Instrument de mesure multivariable pour les liquides et gazEN 01/06/200801/09/200701/12/200501/01/200515/10/2003Language:
French
Version:
01/06/2008
File size:
1.5 MB
File name:
TI053Dfr.pdf
-
-
-
Technical Information (TI)
Proline Promass 80F, 83F Technical Information
-
Technical Information (TI)
English version - 12/2017New version available in EnglishCoriolis Mass Flow Measuring System
The universal and multivariable flowmeter for liquids and gasesEN 21/12/201701/02/2014Language:
English
Version:
21/12/2017
File size:
897.4 KB
File name:
TI00101DEN_1417.pdf
-
-
-
Operating Instruction (BA)
Mise en service promass - Enveloppe de réchauffement
-
Operating Instruction (BA)
French version - 05/2004New version available in Englishpour capteurs Promass F, M, A, I
Language:
French
Version:
28/05/2004
File size:
505 KB
File name:
BA043Dfr.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 80 HART Manuel de mise en service
-
Operating Instruction (BA)
French version - 03/2010New version available in EnglishDébitmètre massique Coriolis
EN 01/03/201001/09/200801/12/200601/12/200501/11/2004Language:
French
Version:
01/03/2010
File size:
3.1 MB
File name:
BA057Dfr_0310.pdf
-
-
-
Operating Instruction (BA)
Proline Promass 80 HART Description des fonctions
-
Operating Instruction (BA)
French version - 09/2008New version available in EnglishDébitmètre massique Coriolis
EN 01/09/200801/12/200501/11/200415/10/2003Language:
French
Version:
01/09/2008
File size:
1.9 MB
File name:
BA058Dfr.pdf
-
-
-
Short Instruction (KA)
Proline Promass 80 Brief Operating Instructions
-
Short Instruction (KA)
English version - 08/2015New version available in EnglishCoriolis Mass Flow Measuring System
EN 06/08/201515/10/201201/07/2007Language:
English
Version:
06/08/2015
File size:
1.3 MB
File name:
KA00023DEN_1415.pdf
-
-
-
Installation Instructions (EA)
EA Replacing cover and O-ring
-
Installation Instructions (EA)
English version - 10/2024New version available in EnglishProline 10, 23, 50, 51, 53, 55, 400, 800, 40, 80, 83, 84, 8ME, 8FF, 8FE
,8CM, 90, 91, 92, 93, 65, 72, 73EN 15/10/202401/10/2018Language:
English
Version:
15/10/2024
File size:
797.3 KB
File name:
EA00098DA2_1624-00.pdf
-
-
-
Installation Instructions (EA)
Replacing cover Installation Instructions
-
Installation Instructions (EA)
English version - 11/2018New version available in EnglishPromass 80F, 83F, 84F Exd
EN 01/11/2018Language:
English
Version:
01/11/2018
File size:
327.3 KB
File name:
EA00100DA2_0218.pdf
-
-
-
Installation Instructions (EA)
I/O-board, subprint, screening sheed Installation Instructions
-
Installation Instructions (EA)
English version - 05/2017New version available in EnglishPromag 50, 51, 53, 55, Promass 40, 80, 83, 84, 8ME, Cubemass DCI 8CN,
CNGmass DCI 8DF, Prosonic Flow 90, 93, t-mass 65EN 01/05/201718/11/2011Language:
English
Version:
01/05/2017
File size:
350.6 KB
File name:
EA00062DA2_1517.pdf
-
-
-
Installation Instructions (EA)
Repair kit cover
-
Installation Instructions (EA)
English version - 04/2014New version available in EnglishInstallatilon Instruction
EN 18/04/2014Language:
English
Version:
18/04/2014
File size:
478.5 KB
File name:
EA01108DDA2_01.14.pdf
-