Hydrostatic
Level measurement
Deltapilot FMB53
Pressure sensor with Contite measuring cell for hydrostatic level measurement
The Deltapilot FMB53 is a cable version with mounting clamp. This device with the Contite measuring cell is typically used in the environmental industries. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.
- F
- L
- E
- X
-
Standard products
- Reliable, robust and low-maintenance
Technical excellence
Simplicity
-
Specialized products
- Designed for demanding applications
Technical excellence
Simplicity
Variable
FLEX selections | Technical excellence | Simplicity |
---|---|---|
Fundamental selection Meet your basic measurement needs |
Technical excellence
|
Simplicity
|
Lean selection Handle your core processes easily |
Technical excellence
|
Simplicity
|
Extended selection Optimize your processes with innovative technologies |
Technical excellence
|
Simplicity
|
Xpert selection Master your most challenging applications |
Technical excellence
|
Simplicity
Variable |
-
Specs at a glance
-
Accuracy
Standard 0,2%
Optional 0,1% -
Process temperature
PE cable: -10°C…70°C / 14°F…158°F
FEP cable: -10°C…80°C / 14°F…176°F -
Pressure measuring range
100mbar...10bar
(1.5psi...150psi) -
Process pressure absolute / max. overpressure limit
40 bar (600 psi)
-
Main wetted parts
Alloy C
316L
Cable (PE/FEP)
optional coating AuPt
optional coating AuRh -
Max. measurement distance
100m (328ft) H2O
-
Material process membrane
316L, AlloyC,
Gold-Rhodium
PE, FEP -
Measuring cell
100 mbar...10 bar
(1.5 psi...150 psi)
-
Quick selection
Individual configuration
-
Benefits
Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects
Modular concept for easy replacement of display or electronics
Seamless and independent system...
-
Field of application
For level measurement.
Process connection: Suspension clamp
Temperature: With PE cable: -10 to +70°C (+14 to +158°F),
with FEP cable: -10 to +80°C (+14 to +176°F)
Measuring range: 0.1 to 10bar / 100m H2O (1.5 to 150psi / 300ft H2O)
Accuracy: ±0.2...
Documents / Manuals / Software
-
Deltapilot M FMB50, FMB51, FMB52, FMB53
Pressure sensor with the CONTITE measuring cell
Condensate-
"resistant offering long-term stability; communication via HART"Technical Information (TI) -
Cerabar M, Deltabar M, Deltapilot M
HART (V 01.00.zz)
Cerabar M PMC51, PMP51/55 Pressure transmitter
Deltabar M
PMD55
Differential pressure transmitter
Deltapilot M FMB50/5Operating Instruction (BA) -
Cerabar M / Deltabar M / Deltapilot M, Operating Instructions
FOUNDATION Fieldbus
Cerabar M PMC51, PMP51, PMP55 Pressure transmitter
Deltabar M PMD55 Differential pressure transmitter
Deltapilot M FMB50 Hydrostatic pressure transmitterOperating Instruction (BA) -
Cerabar M /Deltabar M /Deltapilot M
Operating Instructions
PROFIBUS PA
Cerabar M PMC51, PMP51, PMP55, Pressure transmitter
Deltabar M
PMD55 Differential pressure transmitter
Deltapilot M FMOperating Instruction (BA) -
Deltapilot M FMB50, FMB51, FMB52, FMB53
Brief Operating
Instructions
Pressure sensor with the CONTITE measuring cell
Condensate-resistant offering long-term stability;
HART
communication.Short Instruction (KA)07/16English -
Deltapilot S FMB50, FMB51, FMB52, FMB53
Brief Operating Instructions
Pressure sensor with the CONTITE measuring cell
condensate proofed and long-term stable;
Communication via
PROFIBUS PAShort Instruction (KA)07/16English -
Deltapilot M FMB50, FMB51, FMB52, FMB53
Brief Operating Instructions
Pressure sensor with the CONTITE measuring cell
condensate proofed and long-term stable;
Communication via
FOUNDATION FieldbusShort Instruction (KA)07/16English -
Mounting set for Deltapilot M, Deltapilot S
Installation instruction
Deltapilot M, Deltapilot S
Installation Instructions (EA) -
Cover for Housing F15
Installation instruction
LIquiphant M/S/Fail Safe, Soliphant M, Cerabar M, Deltapilot M
Installation Instructions (EA) -
Housing filter VA
Cerabar, Deltabar, Deltapilot
Installation Instructions (EA) -
Harting plug HAN7D
Installation instruction
Cerabar M/S, Deltabar M/S, Deltapilot M/S
Installation Instructions (EA) -
Display module VU340
Installation instruction
Cerabar M, Deltabar M, Deltapilot M
Installation Instructions (EA) -
Plug 3-pole, M12/M20
Installation instruction
Cerabar S, Deltabar S, Deltapilot S
Installation Instructions (EA) -
Measuring cell
Installation instruction
Deltapilot M FMB51, FMB52, FMB53
Installation Instructions (EA) -
Electronics for Cerabar M, Deltapilot M
Installation Instruction
Cerabar M PMC51, PMP51, PMP55,
Deltapilot M FMB5xInstallation Instructions (EA) -
Installation instruction - Ground terminal T14/T15/T17, F30/F31
Cerabar S, Deltabar S, Deltabar, Cerabar M, Deltabar M, Deltapilot M
Installation Instructions (EA) -
Pressure adapter
Installation instruction
Deltapilot M, Deltapilot S, Waterpilot
Installation Instructions (EA) -
Safety Instruction
Deltapilot M FMB50, FMB51, FMB52, FMB53
CSA Control Drawing
960009067 B
4-20 mA HARTEx Safety Instructions (XA) -
Deltapilot M FMB50, FMB51, FMB52, FMB53
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ex ia IIC T4/T6 Ga/Gb
Ex ia IIC T4/T6 GbEx Safety Instructions (XA) -
Safety Instructions
Deltapilot M FMB50, FMB51, FMB52, FMB53
Ex ia IIC T6...T4 Ga/Gb
Ex ia IIC T6...T4 Gb
IECEx KEM 09.0016Ex Safety Instructions (XA) -
Deltapilot M FMB50, FMB51, FMB52, FMB53
ATEX:
II 1/2 G Ex ia IIC T6...T4 Ga/Gb
II 2 G Ex ia IIC T6...T4 Gb
IECEx:
Ex ia IIC T6...T4 Ga/Gb
Ex ia IIC T6...T4 Gb
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot M FMB50, FMB51, FMB52, FMB53
Ex ic IIC T6...T4 Gc
IECEx KEM 09.0016Ex Safety Instructions (XA) -
Deltapilot M FMB50, FMB51, FMB52, FMB53
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
Ga/Gb Ex ia IIC T6...T4
1Ex ia IIC T6...T4 GbEx Safety Instructions (XA) -
Safety Instructions
Deltapilot M FMB50, FMB51, FMB52, FMB53
II 3 G Ex nA IIC T6...T4 Gc
EG 09 012 XEx Safety Instructions (XA) -
Safety Instruction
Deltapilot M FMB50/51/52/53
FM
Drawing No.: 960014203 A
Drawing Type: Control DrawingEx Safety Instructions (XA) -
Deltapilot M FMB50, FMB51, FMB52, FMB53
ATEX:
II 3 G Ex ic IIC T6...T4 Gc
IECEx:
Ex ic IIC T6...T4 Gc
Safety Instructions
Hydrostatic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Deltapilot M FMB50, FMB51, FMB52, FMB53
CSA Control Drawing
960014221 A
PROFIBUS PA, FOUNDATION FieldbusEx Safety Instructions (XA) -
Deltapilot M FMB50, FMB51, FMB52, FMB53
4-20 mA HART, PROFIBUS PA, FOUNDATION Fieldbus
2Ex ic IIC T6...T4 GcEx Safety Instructions (XA) -
Deltapilot M FMB50/51/52/53
CSA
Drawing No.: 960009067 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot M FMB50/51/52/53
FM
Drawing No.: 960009195 A
Drawing Type: Control DrawingCertificate FM/CSA (ZD) -
Deltapilot M/S, Waterpilot,
Cerabar M/S, Deltabar M/S
Einsatz im Trinkwasserbereich (NSF)
Use in the drinking water sector (NSF)
Utilisation dans le domaine de l’eau potable (NSF)
Special Documentation
Einsatz im Trinkwasserbereich (NSF)
Use in the drinking water sector (NSF)
Utilisation dans le domaine de l’eau potable (NSF)Special Documentation (SD) -
Cerabar M PMC51, PMP51/55
Deltabar M PMD55
Deltapilot M FMB50/51/52/53
Functional Safety data sheet / Datenblatt zur Funktionalen Sicherheit
Special Documentation (SD) -
Cerabar M PMC51, PMP51/55
Deltabar M PMD55
Deltapilot M FMB50/51/52/53
Functional Safety Manual
Process pressure / Differential pressure, Flow / Hydrostatic
Special Documentation (SD) -
Mechanical accessories for pressure measuring devices
Pressure measurement
Special Documentation (SD) -
Instruction Deltapilot FMB53
cable shortening set
Kabelkürzungssatz
cable shortening setSpecial Documentation (SD) -
Deltapilot M FMB50/FMB51/FMB52/FMB53
Einsatz im Trinkwasserbereich (KTW/UBA)
Use in the drinking water sector (KTW/UBA)
Utilisation dans le domaine de l’eau potable (KTW/UBA)Special Documentation (SD) -
List of Tested Devices and Versions ME01
Mitsubishi Electric MELSEC System Q and PROFIBUS for Water &
Wastewater Industry
This document lists all relevant components and devices with versions as
used for
testing of the Reference Topology ME01. All content of this document is
jointly
developed, reviewed and approved by Mitsubishi Electric and
Endress+Hauser as a
common deliverable of Open Integration.Special Documentation (SD) -
M12 socket
Accessories for Liquipoint, Liquitrend, Liquiphant, Ceraphant, Cerabar,
Deltabar, GammapilotSpecial Documentation (SD) -
Deltapilot M: FMB50, FMB51, FMB52, FMB53
Manufacturer information for users regarding software updates (NE53)
Software version V01.00.02 HART
Manufacturer Information (MI) -
Real-time inventory information across production storages
Usage of existing material on stocks and reduction of locked-in
inventory costsIndustry Solutions (SO)09/19English -
The efficient business model with Vendor Managed Inventory
Inventory solution for a chemical distributor
Industry Solutions (SO)09/19English -
More efficient with the supplier-managed inventory business model
Inventory and supply chain solution across depots for a chemical
producerIndustry Solutions (SO)09/19English -
Prevent unscheduled downtimes
With fuel and chemical supply chain management in Primaries
Industry Solutions (SO)09/19English -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)09/19Spanish -
压力测量
用于过程压力、差压、液位和流量测量的专业仪表
Fields of Activities (FA)09/15Chinese -
Basınç Ölçümü
Proses basıncı, fark basınç, seviye ve akış için güçlü enstrümanlar
Fields of Activities (FA)05/15Turkish -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Mesure de pression
Appareils de mesure pour la pression de process, la pression
différentielle, le niveau et le débitFields of Activities (FA)03/17fr -
Misura della pressione
Potenti strumenti per la misura della pressione di processo, pressione
differenziale,
livello e portataFields of Activities (FA)03/17Italian -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Druckmesstechnik
Leistungsfähige Messgeräte für Prozessdruck, Differenzdruck, Füllstand
und DurchflussFields of Activities (FA)03/17German -
Catálogo Medición de Presión
Instrumentos para la medición de presión, presión diferencial, nivel y
caudal de procesoFields of Activities (FA)03/17Spanish -
Pressure measurement
American version: Powerful instruments for process pressure,
differential pressure, level
and flowFields of Activities (FA)03/17English -
Pressure measurement
Powerful instruments for process pressure, differential pressure, level
and flowFields of Activities (FA)03/17English -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17German -
Pomiar ciśnienia
Potężna aparatura do pomiaru
ciśnienia procesowego, różnicy
ciśnień, poziomu i przepływuFields of Activities (FA)03/14Polish -
Deltapilot M, Seilausführung mit Abspannklemme FMB 53
Füllstand-Messwertaufnehmer und Umformer ausgeführt als Druckaufnehmer
zur kontinuierlichen, hydrostatischen Füllstandmessung in offenen
BehälternTender Text04/10German -
Deltapilot M, FMB53
Hydrostatic level transmitter with field housing
Tender Text04/10English -
GSD Single, EH_PA_LE_Deltapilot_M_0x1555_0x01_0x01_PALIB2, 17.04.2014 (Le
vel, Deltapilot M, 0x1555)
PROFIBUS PA,
PROFIBUS System Version: AnyGeneral Station Description (GSD)1.00.00Language neutral -
EDD Single, PDM_PA_LE_DeltapilotM_0x1555_0x01_0x03, 07.01.2019 (Level, Deltapilot M, 0x1555)
PROFIBUS PA,
PDM Version: 6.0 SP4, 8.1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, PDM_HART_LE_DeltapilotM_0x0023_0x01_0x03, 02.09.2014 (Level,
Deltapilot M, 0x0023)
HART,
PDM Version: 6.0 SP5, 8.1 SP1Electronic Data Description (EDD)1.00.00Language neutral -
EDD Single, EH_FF_LE_Deltapilot_M_0x1023_0x01_0x03, 11.07.2016 (Level, Deltapilot M, 0x1023)
FOUNDATION Fieldbus H1,
FOUNDATION fieldbus System Version: AnyElectronic Data Description (EDD)1.00.00Language neutral -
EDD Single, AMS_FF_LE_Deltapilot_M_0x1023_0x01_0x03, 26.07.2016 (Level, Deltapilot M, 0x1023)
FOUNDATION Fieldbus H1,
AMS Version: 12.5Electronic Data Description (EDD)1.00.00Language neutral -
DTM Single, DeltapilotM_FMB5x_FF_FW1_00_zz_Dev_Rev_1, 22.10.2020 (Level, Deltapilot M, 0x1023)
FOUNDATION Fieldbus H1,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.6.55.40Language neutral -
DTM Single, DeltapilotM_FMB5x_PA_FW1_00_zz_Dev_Rev_1, 21.10.2020 (Level, Deltapilot M, 0x1555)
PROFIBUS PA,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.5.155.349Language neutral -
DTM Single, DeltapilotM5x_FMB5x_V1_00_xx, 23.10.2020 (Level, Deltapilot M, 0x0023)
HART,
DeviceCare Version: 1.07.00
Field Xpert - SMT70 Version: 1.05.00
FieldCare Version: 2.15.00Device Type Manager (DTM)1.4.188.39Language neutral -
Faceplate Library, PRM_FF_Package_Level_1_05_00, 29.05.2018 (Level)
FOUNDATION Fieldbus H1,
Plant Resource Manager Version: R3.02, R3.12Faceplate1.05.00Language neutral -
Deltapilot M
Product Code: FMB53-
Declaration Number: HE_00782_01.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
Cerabar M, Deltabar M, Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, PMC51-, PMD55-, PMP51-, PMP55-
Declaration Number: HE_00728_01.17Manufacturer DeclarationGerman , English -
Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Declaration Number: EC_00501_03.17EU DeclarationGerman , English , fr -
Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Declaration Number: EC_00208_03.16EU DeclarationGerman , English , fr -
Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
EU DeclarationGerman , English , fr -
Waterpilot, Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant, Cerabar S, Cerabar M, Cerabar
Product Code: PTP33B-, PTP31B-, PTC31B-, PMP75-, PMP71B-, PMP71-, PMP55-, PMP51B-, PMP51-, PMP23-, PMP21-, PMP11-, PMD78B-, PMD75B-, PMD75-, PMD55B-, PMD55-, PMC71B-, PMC71-, PMC51B-, PMC51-, PMC21-, PMC11-, FMX21-, FMD78-, FMD77-, FMD72-, FMD71-, FMB70-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: EAEC N RU D-DE.DE02.B.11894/20MiscellaneousRussian -
Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: China
Approval Agency: ACMA
Approval Number: EC11013AMiscellaneousEnglish -
Cerabar M, Deltabar M, Deltapilot M
Product Code: PMP55-, PMP51-, PMC51-, PMD55-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: Europe (ATEX)
Approval Agency: DEKRA
Category: II 1/2 G, II 1/2 D, II 2 G
Protection: Ex ta/tb IIIC Txxx°C Da/Db, Ex ia IIC T6 Gb, Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Deltapilot M, Deltapilot S
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-
Protection: Ex ia IIC T6...T2 Ga/Gb, Ex ia IIC T6...T2 Gb, Ex ia IIC T6...T3 Ga/Gb, Ex ia IIC T6...T3 Gb, Ex ia IIIC Txxx°C Da, Ex ia IIIC Txxx°C Da/Db, Ex ic IIC T6...T3 Gc, Ex ta IIIC Txxx°C Da/Db, Ex ta/tc IIIC Txxx°C Da/Dc, Ex ta/tb IIIC Txxx°C Da/DbExplosion ProtectionRussian -
Cerabar M, Deltabar M, Deltapilot M
Product Code: FMB50-, PMP55-, PMP51-, PMD55-, PMC51-, FMB53-, FMB52-, FMB51-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III/1/A,B,C,D,E,F,G
Protection: XP, NI, IS, DIPExplosion ProtectionEnglish -
Cerabar M, Deltabar M, Deltapilot M
Product Code: PMP55-, PMP51-, FMB51-, FMB52-, FMB53-, PMC51-, PMD55-, FMB50-
Region/Country: USA
Approval Agency: FM
Category: I,II,III/1/A,B,C,D,E,F,G/T6
Protection: XP/IS, IS/NI/DIPExplosion ProtectionEnglish -
Cerabar M, Deltabar M, Deltapilot M
Product Code: FMB50-, PMP55-, PMP51-, PMC51-, PMD55-, FMB51-, FMB52-, FMB53-
Region/Country: Brazil
Approval Agency: INMETRO
Protection: Ex ia IIC T6...T3 Ga/Gb, Ex ia IIC T6...T4 Ga/Gb, Ex ia IIC T6...T4 Gb, Ex ia IIIC Txxx°C Da/Db, Ex ic IIC T6...T3 Gc, Ex ic IIC T6...T4 GcExplosion ProtectionPortuguese -
Cerabar M, Deltabar M, Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, PMC51-, PMD55-, PMP51-, PMP55-
Region/Country:
Approval Agency:
Protection: Ex ia, Ex ic, Ex taExplosion Protection -
Cerabar M, Deltabar M, Deltapilot M
Product Code: PMP55-, PMP51-, PMD55-, PMC51-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex ta/tb IIIC Txxx°C Da/Db, Ex ic IIC T6 Gc, Ex ia IIC T6 Gb, Ex ia IIC T6 Ga/GbExplosion ProtectionEnglish -
Deltapilot, Deltapilot M, Cerabar M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: China
Approval Agency: NEPSIExplosion ProtectionEnglish , Chinese -
Cerabar M, Deltabar M, Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, PMC51-, PMD55-, PMP51-, PMP55-
Region/Country: India
Approval Agency: CC(O)E
Protection: Ex iaExplosion ProtectionEnglish -
Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: Europe (ATEX)
Approval Agency: Endress+Hauser
Category: II 3 G
Protection: Ex nA IIC T6 GcExplosion ProtectionGerman , English -
Waterpilot, Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Cerabar S, Cerabar M, Cerabar
Product Code: PMP71B-, PMP71-, PMP51B-, PMP51-, PMD75-, PMD55B-, PMD55-, PMC71B-, PMC71-, PMC51B-, PMC51-, FMX21-, FMX167-, FMD72-, FMD71-, FMB70-, FMB53-, FMB52-, FMB51-, FMB50-
Region/Country: USA
Approval Agency: NSFHygienic EquipmentEnglish -
Product Family: Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: International
Approval Agency: Fieldbus Foundation
Software Version: DEVICE REV. 01, DD-ITK 5.20Fieldbus ConformanceEnglish -
Product Family: Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: International
Approval Agency: PI, PROFIBUS International
Software Version: PROFILE 3.02Fieldbus ConformanceEnglish -
Waterpilot, SYSTEM, Gammapilot M, Gammapilot, Deltapilot S, Deltapilot M, Deltabar S, Deltabar M, Deltabar, Ceraphant T, Ceraphant, Cerabar T, Cerabar S, Cerabar M, Cerabar
Product Code: PMC71B-, PMD55-, PMD75-, PMD75B-, PMD78B-, PMP11-, PMP21-, PMP23-, PMP51-, PMP51B-, PMP55-, PMP71-, PMP71B-, PMP75-, PTC31B-, PTP31B-, PTP33B-, FMB50-, FMB53-, FMB70-, FMD71-, FMD72-, FMD77-, FMD78-, FMG60-, FMX21-, FTG20-, NMS80-, NMS83-, PMC11-, PMC21-, PMC51-, PMC51B-, PMC71-
Approval Agency: TÜVPressure EquipmentGerman , English -
Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: Canada (CRN)
Approval Agency: CRNPressure EquipmentEnglish -
Deltapilot M, Deltapilot S, Waterpilot
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-, FMX167-, FMX21-
Region/Country: Uzbekistan
Approval Agency: UZS
Approval Number: 02.6924MetrologyRussian -
Deltapilot M, Deltapilot S
Product Code: FMB70-, FMB50-, FMB51-, FMB52-, FMB53-
Region/Country: Russia
Approval Agency: Rosstandart
Approval Number: DE.C.30.004.A NO 38961/1MetrologyRussian -
Deltapilot M, Deltapilot S, Waterpilot
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, FMB70-, FMX21-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 11776MetrologyRussian -
Cerabar M, Deltabar M, Deltapilot M
Product Code: FMB50-, FMB51-, FMB52-, FMB53-, PMC51-, PMD55-, PMP51-, PMP55-
Region/Country: International
Approval Agency: TÜVSafety Integrity Level (SIL)English -
Deltapilot M, Deltapilot S
Product Code: FMB50-, FMB52-, FMB53-, FMB70-
Region/Country: International
Approval Agency: RM RSMarineRussian -
Deltapilot M
Product Code: FMB52-, FMB53-
Approval Agency: RM RSMarineRussian -
Deltapilot M
Product Code: FMB50-, FMB52-, FMB53-
Region/Country: International
Approval Agency: ABSMarineEnglish -
Deltapilot M
Product Code: FMB50-, FMB52-, FMB53-
Region/Country: International
Approval Agency: LRMarineEnglish -
Deltapilot M
Product Code: FMB50-, FMB52-, FMB53-
Region/Country: International
Approval Agency: BVMarineEnglish -
Deltapilot M
Product Code: FMB50-, FMB52-, FMB53-
Region/Country: International
Approval Agency: DNVGLMarineEnglish
Accessories / Spare parts
-
-
Nr 19 Order code 71111056
Housing filter VA,EPDM,F15/31/T14/17,1pc
Consists of: vent screw 304. Pressure compensation filter. O-ring EPDM, protection lid. Usage: housing T14, FMD71/FMD72/FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/PMP75. Housing F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55. Housing F15 w/o B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Nr 19 Order code 71219639
Housing filter VA, VMQ, F15, T17, 1 pc.
Consists of: vent screw 304. Pressure compensation filter. O-ring VMQ, protection lid. Usage: housing T17, FMB70, FMD76/FMD77/FMD78, PMC71, PMD70/PMD75, PMP71/ PMP75. Housing F15 bei B1,BB,BD,BF,GA,ID,I1, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
-
-
Nr 20 Order code 52027000
Cover F15 316L, gasket
Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15, stainless steel.
-
Nr 20 Order code 52027002
Cover F15 316L, sight glass, gasket
Sight glass: glass. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15, stainless steel.
-
Nr 20 Order code 52028207
Cover F15, sight glass PC, 316L, gasket
Sight glass: Polycarbonate PC. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53,PMC51, PMP51/PMP55, not for EEx ia (intrinsically safe).
-
Nr 20 Order code 52028267
Cover F15 316L,claw,sight glass,gasket
Sight glass glass. Cover claw. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: dust Ex version, housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53. PMC51, PMP51/PMP55.
-
Nr 20 Order code 52028268
Cover F15 316L, claw, gasket
Cover claw. Gasket 67.5x2.9x1.5, VMQ/PTFE. Usage: housing F15 stainless steel, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Nr 20 Order code 71092705
Cover F30/31/34 Alu, gasket
Material: aluminium. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.
-
Nr 20 Order code 71092707
Cover F30/31/34 Alu, sight glass, gasket
Material: aluminium. Sight glass: mineral glass. O-ring: EPDM. Not for Ex d/XP. Usage: FMB50/FMB51/FMB52/FMB53, FTC260/FTC262, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 21 Order code 52020429
Sealing EPDM, F30/31/34, T14/15, 5 pcs.
Consists of: 5x O-ring 75.87x2.62, EPDM, PTFE, FDA. Usage: housing F30/F31/F34, T14/T15.
-
Nr 21 Order code 52028179
Gasket 67.5x2.9x1.5 VMQ/PTFE, 5 pieces
Profile gasket cover. Usage: housing F15 stainless steel.
-
-
-
Nr 15 Order code 52002449
Cable gland M20 PA, o-ring VMQ
Consists of: cable gland M20, plastic. O-ring 18.72 x 2.62 VMQ. Usage: Housing F15, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55.
-
Nr 15 Order code 52005984
Plug 3p M12/M20, gasket
Consists of: terminal block, gasket. Usage: FMB50/51/52/53, PMC51, PMD55, PMP51/55.
-
Nr 15 Order code 52020762
Plug 2/7-pole, HAN7D, gasket
Consists of: harting plug set. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FMD76/FMD77/FMD78, PMC51, PMC71, PMD55, PMD70/PMD75, PMP51/PMP55, PMP71/PMP75.
-
Nr 15 Order code 71092709
Cable gland M20 PA, O-ring EPDM/PTFE
Consists of: cable gland M20, synthetic. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: housing F30/31, FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.
-
Nr 15 Order code 71092711
Cable gland M20 Metal, gasket
Consists of: cable gland M20, metal. O-ring 17.0x2.0 EPDM + PTFE/FDA. Usage: housing F15/F31, FMB50/FMB51/FMB52/FMB53, PMC51, PMP51/PMP55, housing F30 PMD55.
-
Nr 15 Order code 71092712
Cable entry G1/2, gasket, adapter
Consists of: gasket 18.72x2.51 NBR 70. Adapter M20 > G1/2. Not for Ex d. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.
-
Nr 15 Order code 71120017
Plug valve, F30/F31, seal NBR
Consists of: plug, seal, screw. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Order code 71290825
Ground terminal T14/T15/T17, F30/F31
Consists of: spring washer, screw, earth handle, clamp. Usage: housing T14/T15/T17, FMB70, FMD71/FMD72/ FMD77/FMD78, PMC71, PMP71/PMP75, PMD70/PMD75. Housing F30/F31, FMB50/FMB51/FMB52/ FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 40 Order code 71091670
Display module VU340, Cbar/Dbar/Dpilot M
Digital display, 3 push buttons, snapped bracket. Usage: FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 30 Order code XPP0001-
Electronics FMB5x, PMC51, PMP5x, PMD55
-
-
-
Nr 41 Order code 71094113
Holder Display Dbar/Cbar/Dpilot M
Usage: display module VU340, FMB50/FMB51/FMB52/FMB53, PMC51, PMD55, PMP51/PMP55.
-
-
-
Nr 53 Order code 71102216
Mountingset Cerabar,Deltapilot,Levelflex
Material: 316L. Usage: wall/pipe mounting (2"), FMB50/FMB51/FMB52/FMB53, FMB70, FMP50/FMP51/FMP52/FMP53/FMP54/FMP55/ FMP56/FMP57, PMC51, PMC71, PMP51/PMP55, PMP71/PMP75.
-
-
-
Order code 71220481
-
Order code 71067434
Modification name plate, non Ex
Blank. To fill in the new order code when a non Ex instrument has been modified. Usage: FMB50/FMB51/FMB52, FMR230/FMR231, FMR240/FMR244/FMR245, FMR250,FMR530/FMR532,FTL50/FTL50H/FTL51/ FTL51C/FTL51H, FTL70/FTL71, FTL80/FTL81/ FTL85, NMR81, PMC51, PMC71, PMP51/PMP55.
-
Order code 52006263
M12-female plug connector, cable side
M12 plug socket, cable side Self confectionery connection. Usage: FMB50/FMB51/FMB52/FMB53, FMB70, FTL31/FTL33, FTW23, FTW33,PMP11, PMP21, PMP51, PTC31B, PTP31B, QMW43.
-
Order code 52010285
M12-female plug connec., 90deg, 5m cable
M12 plug socket, cable side. 5m cable PVC, Cu Sn/Ni lock. Usage: FMB50/FMB51/FMB52/FMB53, FTL31/FTL33, FTL51B, FTW23, FTW33, PMC11, PMC21, PMC51, PMP11, PMP21/PMP23, PMP51/PMP55, PTC31B, PTP31B/PTP33B, QMW43.
-
Order code 71114212
M12-female plug connec.,90deg,cable side
Self confectionery connection. Usage: M12 plug socket, cable side.
-
Order code 71125862
-
Order code XPRFID-
-
-
Predecessor