Raman spectroscopy - advanced optical analysis technology
Boost plant safety, ensure product quality, and optimize operations. Raman spectroscopy measures the composition and molecular structure of your samples from lab-to-process in real time.
The Raman flow bench is a key component of the Raman flow assembly system that brings Raman spectroscopy to downstream bioprocessing. This Raman flow assembly system meets the speed demands of downstream by optimizing Raman collection for low-turbidity, low volume samples. Ideally suited for development-scale flow rates, it provides real-time process monitoring, rapid optimization, and control for chromatography and other downstream unit operations.
Downstream: aggregation, protein crystallization, formula stability, product CQA, protein concentration, buffer excipients
Midstream: analyte monitoring in permeate
The Raman flow bench houses a Raman flow cell and easily connects to an Rxn-10 probe paired with a Raman Rxn embedded analyzer
Brings Raman-based process insights and control to downstream bioprocessing unit operations
Incorporates ambient light control as well as signal amplification
Высокотехнологичные продукты
Технический уровень
Простота
Стандартные продукты
Технический уровень
Простота
Высокотехнологичные продукты
Технический уровень
Простота
Специализированные продукты
Технический уровень
Простота
Вариативность
| Выбор категории FLEX | Технический уровень | Простота |
|---|---|---|
Выбор варианта Fundamental Выполнение основных измерительных задач |
Технический уровень
|
Простота
|
Выбор варианта Lean Простое управление основными процессами |
Технический уровень
|
Простота
|
Выбор варианта Extended Оптимизация процессов с помощью инновационных технологий |
Технический уровень
|
Простота
|
Выбор варианта Xpert Управление самыми сложными областями применения |
Технический уровень
|
Простота
Вариативность |
System design and specifications for the Raman flow assembly
(KRFB, KRFC)
| EN | RU | ||
|
30/06/2023
|
|
|
|
Язык: |
Английский |
|
Версия: |
30/06/2023 |
|
Размер файла: |
329.5 KB |
|
Имя файла: |
TI01721CEN_0123.pdf |
System design and specifications for the Raman flow assembly calibration
and verification kit
| EN | RU | ||
|
29/06/2023
|
|
|
|
Язык: |
Английский |
|
Версия: |
29/06/2023 |
|
Размер файла: |
430.9 KB |
|
Имя файла: |
TI01720CEN_0123 Raman flow assembly calibration and verification kit.pdf |
Commissioning, operation, and maintenance details for the
Raman flow assembly (KRFB, KRFC)
| EN | RU | ||
|
30/06/2023
|
|
|
|
Язык: |
Английский |
|
Версия: |
30/06/2023 |
|
Размер файла: |
951.5 KB |
|
Имя файла: |
BA02296CEN_0123.pdf |
Commissioning, operation, and maintenance details for the
Raman flow assembly calibration and verification kit
| EN | RU | ||
|
29/06/2023
|
|
|
|
Язык: |
Английский |
|
Версия: |
29/06/2023 |
|
Размер файла: |
1006.6 KB |
|
Имя файла: |
BA02295CEN_0123 Raman flow assembly calibration and verification kit.pdf |
A list of published technical articles related to Biopharma 4.0
topics with recommendations from Life Science industry experts
at Endress+Hauser.
|
Язык: |
Английский |
|
Версия: |
26/06/2025 |
|
Размер файла: |
363.4 KB |
|
Имя файла: |
PU01611CEN_0125.pdf |
Endress+Hauserが、ライフサイエンス分野の専門知識と、ラマン分
光システム(Raman Rxn2、Raman Rxn4、Rxn-10、Rxn-45、Rxn-46、
バイオマルチオプティックおよびスリーブ、フローフィル、フロー
ベンチ、シングルユース用Ramanオプティックシステム)や水質分
析センサ技術(Liquiline CM44P、CM442、OUSAF44、OUSBT66、
Memosens CPS61E、CLS82E、COS81E、CLS82E)などの信頼性の高い
インラインおよびリアルタイム測定技術によって、世界トップクラ
スのバイオ医薬品メーカーから信頼されている理由を強調したグラ
フィック。
|
Язык: |
Японский |
|
Версия: |
04/10/2024 |
|
Размер файла: |
2.5 MB |
|
Имя файла: |
PU01585CJA_0124_Graphic_EH biopharma trust.pdf |
An overview of the Raman flow assembly (flow bench and flow cell)
used with the Rxn-10 probe in conjunction with a Raman Rxn2
analyzer and a Raman flow assembly calibration and verification kit
for downstream bioprocessing (powered by Kaiser Raman technology).
|
Язык: |
Английский |
|
Версия: |
31/05/2023 |
|
Размер файла: |
837 KB |
|
Имя файла: |
PU01517CEN_0123.pdf |
This self-assessment questionnaire helps pharmaceutical and API
manufacturers evaluate their readiness for implementing online
Raman spectroscopy. A simple scoring system identifies potential
infrastructure, integration, and process monitoring challenges, helping
teams assess deployment complexity and prepare for successful
real-time analytical monitoring.
|
Язык: |
Английский |
|
Версия: |
24/08/2026 |
|
Размер файла: |
111.2 KB |
|
Имя файла: |
PU01649CEN_0126.pdf |
This self-assessment questionnaire helps bioprocessing teams evaluate
analytical costs and delays associated with scaling up from laboratory
development to production. A scoring system helps identify optimization
opportunities and assess the value of real-time monitoring using online
Raman spectroscopy.
|
Язык: |
Английский |
|
Версия: |
24/08/2026 |
|
Размер файла: |
111.4 KB |
|
Имя файла: |
PU01647CEN_0126.pdf |
Graphic illustrating the core elements of Biopharma 4.0 including
product lifecycle stages, role of PAT/QbD, and 12 key advanced
technologies for scientists and process engineers in the Life
Sciences, applicable to Raman spectroscopy systems (Raman
Rxn2, Raman Rxn4, Rxn-10, Rxn-45, Rxn-46, bio multi optic and
sleeve, flow cell and flow bench, Raman optic system for single
use, and Raman calibration & verification kits).
|
Язык: |
Английский |
|
Версия: |
22/05/2025 |
|
Размер файла: |
481.6 KB |
|
Имя файла: |
PU01614CEN_0125.pdf |